Download Print this page

Panasonic CN-66A Instruction Manual page 2

Advertisement

INSTRUCTION
MANUAL
Connector
CN-66A
MJE-CN66A No.0036-06V
Thank you very much for purchasing Pana-
sonic products. Read this Instruction Manual
carefully and thoroughly for the correct and
optimum use of this product. Kindly keep
this manual in a convenient place for quick
reference.
1
OUTLINE
This is a connector which can connect to
the DPC-100 series, etc.
Housing: PAP-06V-S
[manufactured by J.S.T. MFG CO., LTD]
Contact: SPHD-001T-P0.5
[manufactured by J.S.T. MFG CO., LTD]
2
CAUTIONS
This product has been developed / pro-
duced for industrial use only.
Be sure to use a crimping tool for crimp-
ing work.
Do not reuse a contact which has been
crimped once or inserted into the hous-
ing, as its performance cannot be guar-
anteed.
Always connect or disconnect the cable
attached connector by holding the con-
nector. Never pull the cable, since it may
cause a cable break.
3
SUITABLE CABLE
Lead wire diameter
Lead wire
Conductor cross-section area
Conductor cross-
2
0.12 to 0.32mm
(AWG26 to 22)
section area
Lead wire diameter
ø1.0 to ø1.5mm
Wire material
Soft, twisted copper wire
Note: For the cable length, refer to the Instruction Manual
of the device to which it is connected.
4
ASSEMBLY PROCEDURE
1. Use a suitable cable and prepare its end,
ZLWK D VWULSSHU HWF DV JLYHQ LQ WKH ¿JXUH
below.
* When processing, make sure that the core
wires are not scratched or damaged.
In case of cabtyre cable
(20mm)
Sheath
2.1mm
Lead wire
In case of single lead wire
2.1mm
Lead wire
2. Setting the contact in the groove of the
H[FOXVLYH FULPS WRRO DV VKRZQ LQ WKH ¿JXUH
below, insert the lead wire into the contact
and crimp.
Contact
Lead wire
<Recommended>
Crimping tool: YC-610R (AWG26 to 24)
[manufactured by J.S.T. MFG CO., LTD.]
YC-611R (AWG22)
[manufactured by J.S.T. MFG CO., LTD.]
3. After crimping, make sure to confirm that
the crimp height is appropriate.
Crimp height (mm)
S h e a t h d i -
Cable size
ameter (mm)
Core wire
Sheath (Note)
AWG26
1.3
0.6 to 0.7
AWG24
1.5
0.65 to 0.75
AWG22
1.4
0.7 to 0.8
Note: The crimp height of sheath is a reference value.
Also, confirm that crimping is proper, as
VKRZQ LQ WKH ¿JXUH EHORZ
In case the crimping is incorrect, cut the
cable and repeat the procedure from Step 1.
0.3 to 0.6mm
Core wire should be visible
Contact
Lead wire
Crimp height
Good
Not good
Not good
Examples of incorrect crimping
Longer protrusion of core wire
Shorter protrusion of core wire
Incorrect crimping of
Uncrimped core wire strand
wire sheath
Insulation caught in
wire barrel
 $V VKRZQ LQ WKH ¿JXUH EHORZ LQVHUW WKH
contact to the end of the wire inlet of the
housing.
$IWHU LQVHUWLQJ PDNH VXUH WR FRQ¿UP WKDW
the locking is proper by pulling lightly
(10N) at the cable.
1.7
1.8
1.8
Housing
The pin position differs with the type of
device connected. Connect correctly after
FRQ¿UPLQJ WKH WHUPLQDO DUUDQJHPHQW RI WKH
device to which it is connected.
http://panasonic.net/id/pidsx/global
2YHUVHDV 6DOHV 'LYLVLRQ +HDG 2I¿FH
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2012
PRINTED IN JAPAN

Advertisement