Introduction
The LG+5V boiler module 868MHz is a receiver with 5V DC to control ON/
OFF of Boiler or other heat system via the RF signal transmitted from the
thermostat.
Product Compliance
This product complies with the essential requirements and other
relevant provisions of Directives (RED) 2014/53/EU and 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the
following internet address: www.salus-controls.com.
868MHz-868.8MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your
device completely dry. Disconnect your device before cleaning it with
a dry cloth.
Terminal connections
Terminal Identifier
1
2
3
4
5
Compatibility
The LG+V5 is compatible with the following SALUS products
RT310TX
RT510TX
Description
DC power supply (+)
DC +
DC power supply (-)
DC -
Common input
COM
Normal Open
NO
Normal Closed
NC
ERT20TX
RT310iTX
iT500TR
Switch Position
1
The boiler receiver is off.
2
AUTO. RX will automatically
receive the RF signal from your
compatible SALUS device and
controls relay output.
3
Manual mode - Manual Override
(Note this mode will run your boiler continuously)
Installation
i
Note: When removing blanking plate also remove visible
thermostat link plug do not remove any internal link.
1. Ensure boiler is isolated and switched off.
2. Pull down control panel cover.
3. Remove existing mechanical timer and unscrew from plate.
4. Reverse the procedure to install the RXBC5V.