Salus SPMV32 Instruction Manual
Salus SPMV32 Instruction Manual

Salus SPMV32 Instruction Manual

3 port motorised valve (22 mm)
Hide thumbs Also See for SPMV32:

Advertisement

Quick Links

Salus
SPMV32 (3 port 22mm) Manual.qxd:Layout 1
9/1/11
09:48
Page 1
3 PORT MOTORISED
VALVE (22 mm)
Model No SPMV32
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for Salus SPMV32

  • Page 1 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 1 3 PORT MOTORISED VALVE (22 mm) Model No SPMV32 Instruction Manual...
  • Page 2 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 2 SPMV32 INSTRUCTION MANUAL...
  • Page 3: Product Compliance

    • EC Marking Directive 93/68/EEC SAFETY INFORMATION These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model. These instructions are intended to apply in the United Kingdom only, and should be followed along with any other statutory obligations.
  • Page 4 There are two types of motorised valve used in domestic heating systems: two port (also called zone valves), and three port (also called mid position valves). Salus Controls offers both types of valve in a range of standard port sizes.
  • Page 5: Before Installation

    If you are not sure how to install this motorised valve consult either with a qualified electrician, heating engineer or your boiler / heating system supplier for advice on how to continue. NOTE: The SPMV32 has a detachable power lead and LED indicator lights. SPMV32 INSTRUCTION MANUAL...
  • Page 6: Operation

    Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 6 OPERATION Three way valves This type of three way motorised valve has port A normally closed with no power to the valve. In this state, water can flow from port AB to port B. When the electrical supply is activated, the actuator motor overcomes the force of the internal spring and closes port B.
  • Page 7 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 7 MANUAL LEVER There is a lever on the side of the actuator cover: this lever allows manual operation of the valve, e.g. for refilling and draining of the system or if the actuator fails.
  • Page 8: Maintenance

    (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user serviceable parts within the unit; any servicing or repairs should only be carried out by Salus Controls or their appointed agents.
  • Page 9: Product Specification

    Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 9 PRODUCT SPECIFICATION Model: SPMV32 Type: Motorised valve designed for domestic heating applications. Electrical Switching Voltage: 230V AC / 50Hz Power Consumption: Response Opening: 12 seconds Closing: 5 seconds Differential Pressure...
  • Page 10 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 10 Operating Temperatures Min Fluid Temperature: 5 ºC Max Fluid Temperature: 88 ºC Environment Operating Temperature: 0 ºC to + 50 ºC Storage Temperature: - 20 ºC to + 60 ºC...
  • Page 11 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:48 Page 11 SPMV32 INSTRUCTION MANUAL...
  • Page 12 Salus SPMV32 (3 port 22mm) Manual.qxd:Layout 1 9/1/11 09:49 Page 12 salus-tech. Sales Email: sales@salus-tech.com Tel: 01226 323961 Technical Email: tech@salus-tech.com Tel: 01226 323961 Salus Controls plc, Salus House, Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP...

Table of Contents