Advertisement

ACCESSING THE FRONT PANEL CONFIGURATION EDITOR.

Ensure the engine is at rest and the module is in STOP mode by pressing the
Ensure the engine is at rest and the module is in STOP mode by pressing the
Stop/Reset
button. Press the Stop/Reset
simultaneously.
If a module security PIN has been set, the PIN number request is then shown :
If a module security PIN has been set, the PIN number request is then shown :
Press the
button the first digit will flash to enable the pin to be entered.
Press
(up) or
Press
(right) when the first digit is correctly entered. The digit you have
just entered will now show '#' for security.
Repeat this process for the other digits of the PIN number. You can press
Repeat this process for the other digits of the PIN number. You can press (left) if
you need to move back to adjust one of the previous digits.
When
is pressed after editing the final PIN digit, the PIN is checked for
is pressed after editing the final PIN digit, the PIN is checked for
validity. If the number is not correct, you must re-enter the PIN.
If the PIN has been successfully entered (or the module PIN has not been enabled),
If the PIN has been successfully entered (or the module PIN has not been enabled),
the editor is displayed :

EDITING A PARAMETER

Enter the editor as described above.
Press the
wish to view/change.
To edit the parameter, press
highlighted in blue to indicate that you are editing the value.
Press
or
value.
Press
to save the value. The parameter ceases flashing to indicate that it
has been saved.
To exit the editor at any time, press and hold the

DIMENSIONS AND MOUNTING

For flat surface mounting in a Type 1 enclosure to meet UL requirements
For flat surface mounting in a Type 1 enclosure to meet UL requirements

DIMENSIONS

310.0mm x 161.5mm x 42mm
D E E P S E A E L E C T R O N I C S
D E E P S E A E L E C T R O N I C S
8 7 2 1 I N S T A L L A T I O N I N S T R U C T I O N S
I N S T A L L A T I O N I N S T R U C T I O N S
(down) to adjust it to the correct value.
when the first digit is correctly entered. The digit you have
or
to enter edit mode. The parameter is
down buttons to change the parameter to the required
buttons to change the parameter to the required
The parameter ceases flashing to indicate that it
(12.2" x 6.4" x 1.6")
and Info
buttons
to cycle to the parameter you
or
button.

PANEL CUTOUT

PANEL CUTOUT
282mm x 136mm
282mm x 136
053-072
ISSUE 4
you
:
(11.1" x 5.4")

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8721 and is the answer not in the manual?

Questions and answers

Summary of Contents for DSE 8721

  • Page 1 D E E P S E A E L E C T R O N I C S D E E P S E A E L E C T R O N I C S 053-072 8 7 2 1 I N S T A L L A T I O N I N S T R U C T I O N S I N S T A L L A T I O N I N S T R U C T I O N S ISSUE 4 ACCESSING THE FRONT PANEL CONFIGURATION EDITOR.
  • Page 2 ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR • The ‘running’ editor can be entered while the engine is running. All protections remain active if the engine is running while the running editor is entered. • Press and hold the button to enter the running editor. ADJUSTABLE PARAMETERS (Running editor) •...

Table of Contents