6.2.2.
Demodulator (Receive) Adjustment
1.
Connect the oscilloscope to U30 pin 14.
2.
Adjust R81 for maximum signal amplitude.
3.
Press the [SPACE BAR]. The on-screen frequency counter should read 2310 Hz.
4.
Connect the oscilloscope to U30 pin 1.
5.
Adjust R96 for maximum signal amplitude.
6.
Type
Q
6.3.
Functional Test
1.
Type
MY AEA
The monitor should display
2.
Type
C AEA
The monitor should display
3.
Type a few characters and press [RETURN]. These same characters should be
echoed back to the terminal.
4.
Type
^C
The monitor should display
5.
Type
K
6.
Adjust the PK-232's
PK-232's front panel is lit. Type several characters and a [RETURN]. Observe the
SEND LED
7.
Adjust the
Observe that the
echoed on the screen.
8.
Adjust R155 (AFSK output level) to 200 millivolts peak-to-peak as measured at the
junction of C59 and R160.
9.
Type ^C.
10.
Type
VHF OFF
The monitor should echo
11.
Type
HB 300
The monitor should echo
12.
Type
K
13.
Type several characters followed by a [RETURN].
PK232TM Rev. A 5/87
to exit the calibration routine.
[RETURN].
MYCALL was AAA
[RETURN].
*** CONNECTED TO AEA
<CTRL-C>.
CMD:
[RETURN] to enter CONVERSE mode.
THRESHOLD
on the front panel. The
THRESHOLD
control counterclockwise until the
SEND LED
[RETURN].
VHF was ON
[RETURN].
HBAUD was 1200
[RETURN].
CHAPTER 6 – ADJUSTMENTS AND TESTS
.
.
control clockwise until the
SEND LED
should NOT be lit.
is lit and that the characters that were typed are
.
.
6-3
.
on the
DCD LED
DCD LED
is extinguished.
Page 38