Si001559E
Step
5
Remove the protection
bushing.
6
Disconnect the
compressor lead wires
and the overload
protector.
7
Remove the putty.
8
Heat up the 4 brazed
parts and remove the
four way valve.
Removal Procedure
Electronic Expansion Valve Coil / High Pressure Switch / Four Way Valve
Procedure
Protection bushing
Overload
protector
Putty
Four way valve
Brazed
part
U (red)
V (yellow)
W (blue)
(R22244)
(R22245)
Points