Daikin RKM18PVMK Removal Procedure page 12

18000/24000/28000 btu/h class
Hide thumbs Also See for RKM18PVMK:

Advertisement

Electrical Box
Step
7
Open the sound blanket
(top) and detach the
discharge pipe
thermistor.
8
Cut the clamp and pull
out the outdoor heat
exchanger thermistor.
9
Remove the 3 screws
and remove the
electrical box.
10
Procedure
Sound blanket (top)
Discharge pipe thermistor
Electrical box
Be careful not to lose the
fixture for the thermistor.
(R22219)
Be careful not to lose the clip
for the thermistor.
Clamp
Outdoor heat
exchanger
thermistor
(R22221)
(R22222)
Si001559E
Points
Fixture
(R22220)
Clip
(R3264)
Removal Procedure