Riello RS 650/E BLU Installation, Use And Maintenance Instructions

Gas burner

Advertisement

Quick Links

Installation, use and maintenance instructions
Gas burner
GB
Quemador de gas
E
Modulating operation
Funcionamiento modulante
CODE - CÓDIGO
MODEL - MODELO
TYPE - TIPO
20026361
RS 650/E BLU
1122T1
20027770 (4) - 04/2012

Advertisement

Table of Contents
loading

Summary of Contents for Riello RS 650/E BLU

  • Page 1 Installation, use and maintenance instructions Gas burner Quemador de gas Modulating operation Funcionamiento modulante CODE - CÓDIGO MODEL - MODELO TYPE - TIPO 20026361 RS 650/E BLU 1122T1 20027770 (4) - 04/2012...
  • Page 3: Table Of Contents

    Contents Declarations....................................3 Information and general instructions............................4 Information about the instruction manual ........................4 2.1.1 Introduction.................................. 4 2.1.2 General dangers................................4 2.1.3 Danger: live components............................. 4 Guarantee and responsibility............................5 Safety and prevention................................6 Introduction.................................. 6 Personnel training ............................... 6 Technical description of the burner ............................
  • Page 4 Contents Combustion air adjustment ............................27 Air adjustment for maximum output ...........................27 Air/fuel control and power modulation system ......................27 Adjustment pressure switches ...........................28 6.8.1 Air pressure switch - CO check..........................28 6.8.2 Max. gas pressure switch ............................28 6.8.3 Min. gas pressure switch ............................28 6.8.4 Pressure switch PVP kit .............................28 Burner operation ................................29...
  • Page 5: Declarations

    The quality is guaranteed by a quality and management system certified in accordance with UNI EN ISO 9001. Manufacturer's Declaration RIELLO S.p.A. declares that the following products comply with the NOx emission limits specified by German standard “1. BImSchV reliese 26.01.2010”.
  • Page 6: Information And General Instructions

    Information and general instructions Information and general instructions Information about the instruction manual 2.1.1 Introduction 2.1.3 Danger: live components The instruction manual supplied with the burner: This symbol indicates operations which, if not car-  is an integral and essential part of the product and must not ried out correctly, lead to electric shocks with le- be separated from it;...
  • Page 7: Guarantee And Responsibility

    Information and general instructions Guarantee and responsibility The manufacturer guarantees its new products from the installa- tion date, in accordance with the regulations in force and/or the sales contract. At the moment of the first start-up, check that the burner is integral and complete. Failure to observe the information given in this manual, operating negligence, incorrect installa- tion and the carrying out of non authorised modifi-...
  • Page 8: Safety And Prevention

    Safety and prevention Safety and prevention Introduction The burners have been designed and built in compliance with the type and pressure of the fuel, the voltage and frequency of the current regulations and directives, applying the known technical electrical power supply, the minimum and maximum deliveries for rules of safety and envisaging all the potential danger situations.
  • Page 9: Technical Description Of The Burner

    BASIC DESIGNATION EXTENDED DESIGNATION Models available Designation Electrical supply Starting Code RS 650/E BLU 400V-50 Hz Star/Delta 20026361 Burner categories - Countries of destination Gas category Destination country AT - CH - CZ - DK - EE - ES - FI - GB - GR - HU - IE...
  • Page 10: Technical Data

    Technical description of the burner Technical data Model RS 650/E BLU Output 1430/3000 - 6550 min - max Delivery kg/h 121/253 - 552 Fuel Natural gas: G20 (methane) - G21 - G22 - G23 - G25 Gas pressure at maximum delivery mbar 58/86.5...
  • Page 11: Burner Weight

    Technical description of the burner Burner weight The weight of the burner complete with its packaging is shown in table. Model RS 650/E BLU D10554 Fig. 1 Overall dimensions The maximum dimensions of the burner are given in (Fig. 2).
  • Page 12: Firing Rate

    Technical description of the burner Firing rate MAXIMUM OUTPUT must be selected in the hatched area of the The firing rate area values (Fig. 3) have been ob- diagram (Fig. 3). tained considering a surrounding temperature of MINIMUM OUTPUT must not be lower than the minimum limit 20 °C, and an atmospheric pressure of 1013 mbar shown in the diagram.
  • Page 13: Burner Description

    Technical description of the burner 4.10 Burner description D10569 Fig. 5 Lifting eyebolts 19 Air pressure test point 20 Maximum gas pressure switch with pressure test point Fan motor 21 UV sensor Air gate valve servomotor 22 Hinge for opening burner Gas pressure test point 23 Air pressure test point pressure test point “+”...
  • Page 14: Description Of Panel Board

    Technical description of the burner 4.11 Description of panel board D3088 Fig. 6 Terminal strip for kits 16 Phase sequence relay Relay outlet - clean contacts 17 Main supply terminal strip Electronic cam transformer 18 Entry for power cables and external leads Electronic cam setting device 19 Thermal cut-out Ignition transformer...
  • Page 15: Control Box For The Air/Fuel Ratio (Lmv51

    Technical description of the burner 4.13 Control box for the air/fuel ratio (LMV51...) Warning notes To avoid injury to persons, damage to prop- erty or the environment, the following warn- ing notes must be observed! The LMV51... is a safety device! WARNING Do not open, interfere with or modify the unit.
  • Page 16 Technical description of the burner Electrical wiring of the infrared flame detection probe. • Observe the permissible cable lengths. It is important to achieve practically disturbance- and loss-free • The detection probe is not protected against electrocution signal transmission: risks and must be protected against accidental contact. •...
  • Page 17: Actuator (Sqm48.4

    Technical description of the burner 4.14 Actuator (SQM48.4..) Warning notes To avoid injury to persons, damage to prop- erty or the environment, the following warn- ing notes should be observed! WARNING Do not open, interfere with or modify the ac- tuators! ...
  • Page 18: Installation

    Installation Installation Notes on safety for the installation After carefully cleaning all around the area where the burner will The installation of the burner must be carried out be installed, and arranging the correct lighting of the environ- by qualified personnel, as indicated in this manual ment, proceed with the installation operations.
  • Page 19: Operation Position

    For boilers with front flue passes 1) (Fig. 13) or flame inversion RS 650/E BLU chambers, protective fettling in refractory material 5) must be in- serted between the boiler fettling 2) and the blast tube 4).
  • Page 20: Securing The Burner To The Boiler

    Installation Securing the burner to the boiler Create a suitable hoisting system by hooking onto the rings 3)(Fig. 13), removing the fastening screws 7) securing the cover The coupling of the burner-boiler must be air- 8) first. tight.  Slip the thermal protection (standard equipment) onto the WARNING blast tube 4).

This manual is also suitable for:

20026361