Leviton RZCS1 Installation Instructions

Leviton RZCS1 Installation Instructions

1-scene controller/matching switch remote

Advertisement

Quick Links

DI-000-RZCS1-00C

WARNINGS AND CAUTIONS

:
• ON/OFF LED for remote load control.
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Vizia™ RF RZCS1 1-Scene Controller does not control the load, but provides 3-way or 4-way applications to operate with Vizia
• Recommended minimum wall box depth is 2-1/2".
INTRODUCTION
Leviton's Vizia
TM
RF components are designed to communicate with
each other via Radio Frequency (RF) to provide remote control of your
lighting. Using RF technology allows Leviton to provide the greatest
signal integrity possible. Each module in Leviton's Vizia
TM
RF component
line is a Z-Wave
TM
enabled device. In a Z-Wave
TM
network, each device
is designed to act as a router. These routers will re-transmit the RF signal
from one device to another until the intended device is reached. This
ensures that the signal is received by its intended device by routing the
signal around obstacles and radio dead spots. The 1-Scene Controller/
Matching Switch Remote is compatible with any Z-Wave™ enabled
network, regardless of the manufacturer and can also be used with other
devices displaying the Z-Wave™ logo.
FEATURES
• This is a Z-Wave
Controller
TM
• 3-way or 4-way control without traveler wires
• Can call 1 scene
• ON/OFF LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled devices

Tools needed to install your 1-Scene Controller:

Slotted/Phillips Screwdriver
Electrical Tape
Pencil
Cutters

Changing the color of your 1-Scene Controller:

Your 1-scene controller includes three color options. The controller ships
with the White frame attached. To change color of frame, proceed as
follows:
Push in
line up tabs
side at tab
and press in
to release
side to attach

INSTAllING YOUR 1-SCENE CONTROllER

NOTE: Use check boxes when Steps are completed.
WARNING:
TO AVOID FIRE, SHOCK OR DEATH; TURN
Step 1
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Identifying your wiring application (most common):
Step 2
NOTE: If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
2
1
3
2

Preparing and connecting wires:

Step 3
This 1-scene controller can be wired using side wire terminal
Pliers
screws or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
Ruler
Cut
(if necessary)
Side Wire Connection
Back Wire (either hole may be used)
Side wire terminals accept #14
Back wire openings use #14-12 AWG
AWG solid wire copper only.
solid wire copper only.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
1-Scene Controller/
Matching Switch Remote
Cat. No. RZCS1
120VAC, 60Hz
INSTAllATION INSTRUCTIONS
WARNINGS AND CAUTIONS
• No traveler wires are needed. Remote controls via radio frequency (RF) technology.
• Can call one (1) scene ON/OFF with advanced Programmer/Remote (see RZCPG).
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
TM
RF switches.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Wiring Application:
Step 4
1-Scene Controller

WIRING 1-SCENE CONTROllER:

Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to terminal screw marked "BK".
• Line Neutral wall box wire to terminal screw marked "WH".
• Proceed to Step 5.
Testing your 1-Scene Controller prior to
Step 5
1. Line (Hot)
mounting in wall box:
2. Neutral
3. Ground
• Restore power at circuit breaker or fuse.
• LED should turn ON.
5/8"
Strip Gage
If lED does not turn ON, refer to the
(1.6 cm)
(measure bare
wire here)
Including 1-Scene Controller into Z-Wave
Step 6
Network:
NOTES:
If using a non-Leviton Programmer/Remote, refer to the Programmer/
Remote instruction sheet.
1-scene controllers included into a Z-Wave
after you have included all other devices.
A) If using a Leviton Z-Wave
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Press the center button to
select Network. Press the center button to <Include Node>.
Compatible with
:
Step 6 cont'd
B) If using RZCPG Programmer/Remote, you will be prompted to place
1-scene controller into programming mode.
C) To access Program mode, engage the air gap switch by gently
Hot (Black)
WH
BK
pulling the bottom of the push pad until it lifts out of the frame and a
click is heard (refer to figure). Wait 5 seconds and then press the
Green
Ground
push pad back into the frame and hold push pad until the LED turns
Line
Amber. Release the push pad and the LED should blink Amber. You
120VAC, 60Hz
are now in Programming mode.
NOTE: If the LED on the 1-scene controller turns solid Red while
including, there has been a communication error.
Neutral (White)
D) While standing close to the 1-scene
controller (approximately 2-5 ft.), press
the center button on the Programmer/
Remote to <Include> device in the
network. NOTE: Only one device may
be included at any time.
E) The Primary Programmer/Remote
will assign a Home ID, Node ID, and
Name for this device.
NOTE: This information will be stored
in the Programmer/Remote to be used
• Position all wires to provide room in
for future reference.
outlet wall box for device.
NOTE: You may name or edit the node
• Ensure that the word "TOP" is facing up
of this device at this time.
on device strap.
F) The 1-scene controller is now
• Partially screw in mounting screws in
installed in the network.
wall box mounting holes.
G) After all devices are included into the
NOTE: Dress wires
network, the controller must be updated to allow proper network
with a bend as
function. To update controller proceed as follows:
shown in diagram
in order to relieve
• I f using a non-Leviton Programmer/Remote, refer to the
stress when
mounting device.
• I f using Leviton Z-Wave
center button to select
System Setup Menu. Press the
center button to select Network.
Press the center button to select
Update "cntrl". When prompted, press
push pad on the 1-scene controller.
TM
• W ait until the RZCPG Programmer/
NOTE: If the 1-scene controller has
been successfully Included in the
network and the user tries to Include
network must be updated
TM
it again without first excluding it from
the network, the controller will retain
TM
Programmer/Remote, Cat. No. RZCPG,
the first node ID it had received and
ignore the second.
TM
enabled products!
Gently lift bottom of
push pad out
Programmer/Remote instruction sheet for updating controller.
TM
Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll
down to System Setup. Press the
Cat. No. RZCPG
Remote confirms completion.
Menu
Update is done.
Button
Center
1
ON
OFF
Button
2
ON
OFF
3
ON
OFF
4
ON
OFF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RZCS1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Leviton RZCS1

  • Page 1 F) The 1-scene controller is now • Partially screw in mounting screws in installed in the network. wall box mounting holes. G) After all devices are included into the NOTE: Dress wires network, the controller must be updated to allow proper network with a bend as function. To update controller proceed as follows: shown in diagram in order to relieve • I f using a non-Leviton Programmer/Remote, refer to the stress when Programmer/Remote instruction sheet for updating controller. mounting device. • I f using Leviton Z-Wave press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Press the center button to select Network. Press the center button to select Update "cntrl". When prompted, press push pad on the 1-scene controller.
  • Page 2 obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

This manual is also suitable for:

Vizia rf rzcs1

Table of Contents