Navien NCB300-28K Installation & Operation Manual page 11

Condensing combi boiler
Hide thumbs Also See for NCB300-28K:
Table of Contents

Advertisement

Specifications
Flue exhaust/Air intake system diameters
Max. gas pipe pressure drop
Max. horizontal coaxial length Ø60/100
Max. vertical coaxial length Ø60/100
Equivalent elbow length @ 90° Ø60/100
Equivalent elbow length @ 45° Ø60/100
Max. horizontal coaxial length Ø80/125
Max. vertical coaxial length Ø80/125
Equivalent elbow length @ 90° Ø80/125
Equivalent elbow length @ 45° Ø80/125
Equivalent length of adapter Ø60/100 => Ø80/125
Max. dual duct length Ø80/80
Equivalent elbow length @ 90° Ø80
Equivalent elbow length @ 45° Ø80
Hydraulic connection diameter
Dimensions (Width x Depth x Height)
Total boiler weight (lift weight)
10
About the Boiler
Unit
mm
Pa
m
m
m
m
m
m
m
m
m
m
m
m
Central Heating
mm
DHW
mm
Gas supply
mm
mm
kg
NCB300-28K
NCB300-37K
Coaxial Ø60/100 and Ø80/
125–Dual duct Ø80/80
167
294
8
8
1.3
1.0
27
28
2.2
1.0
0.5
9
2.2
1.4
22
15
22
395 x 283 x 680
29
33
NCB300-41K
294
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncb300-37kNcb300-41k

Table of Contents