The 230V line must be connected only by a professional electrician.
The Electrical supply must be disconnected before working on the device.
Improper handling may void warranty.
4. Product Scope
Matrix Amplifier for 4 speaker zones (4-8 ohms/70V/100V).
5. Intended use
Indoors
6. Improper use
The device is not suitable for outdoor operation. The ambient temperature should not exceed 30 ° C.
7. Specifications AMP 4200
Power Supply
Output Power
Protection
Dimensions (H/W/D)
Weight
Operating Temperature
Input:
Sensitivity
*)
Impedance
Type
Output:
Speaker
Audio Performance:
Type
Frequency Response
THD+N
S/N Ratio
Version (modifications reseverd)
AMP 4200
111-425-04-001-00
100-240 V AC, 50/60 Hz
4 x 200 Watt rms
Thermal, over-current, over-voltage, short
circuit protection
44 x 430 x 320 mm
5.5 kg
5 ... 30 °C
0 /+6 dBV (variable)
22 kOhm
4 x Phoenix, 3Pin
Bzw. 4 x RCA
Trigger: 12VdC (3,5mm mono jack)
4 x Phoenix, 2Pin
Class D
20  20kHz ± 1dB
> 1% @ 1 kHz, Rated Power
≥ 90 dB (A-weighted)
Seite 2 of 17