Leviton Decora Multi-Remote MSE0R-1 Installation Instructions
Leviton Decora Multi-Remote MSE0R-1 Installation Instructions

Leviton Decora Multi-Remote MSE0R-1 Installation Instructions

Leviton multi-remote mse0r-1 dimmers: install guide

Advertisement

• Leviton's Decora
C O L L E C T I O N B Y L E V I T O N
• Allows remote operation of various Leviton
WARNING:
CODES AND REGULATIONS.
WARNING:
3-Way (Multi-location)
QUALIFIED ELECTRICIAN.
120VAC, 60Hz
WARNING:
EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, OR A
Multi-Remote
TM
MOTOR - OR TRANSFORMER - OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-
VOLTAGE LIGHTING.
Cat. No. MSEØR-1
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. THE CAT. NO. MSEØR-1 IS USED FOR REMOTE CONTROL OF
For use with Electronic Low-Voltage dimmers
2. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.
INSTALLATION INSTRUCTIONS
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE

MULTI-GANG INSTALLATION:

When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully
bend side sections back and forth until they break off (see Figure 1).

TO INSTALL:

DI-000-MSE0R-00A
1.
2. Remove existing wallplate and switch or dimmer, if applicable.

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials
4. Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly
and workmanship under normal and proper use for two
years from the purchase date. Leviton's only obligation is
to correct such defects by repair or replacement, at its
option, if within such two year period the product is returned
prepaid, with proof of purchase date, and a description of
5. Carefully position all wires to provide room
the problem to Leviton Manufacturing Co., Inc., Att:
Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591. This
warranty excludes and there is disclaimed liability for labor
6. Restore power at circuit breaker or fuse.
for removal of this product or reinstallation. This warranty
is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any
labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness
for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any
such implied warranty, including merchantability and fitness
for a particular purpose, is limited to two years. Leviton is
not liable for incidental, indirect, special, or consequential
7. Restore power at circuit breaker of fuse.
damages, including without limitation, damage to, or loss
of use of, any equipment, lost sales or profits or delay or
failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this
warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com
DI-000-MSE0R-00A
DI-000-MSE0R-00A
1

FEATURES

®
Style design
• Offers multiple location remote dimming
• Fits standard wall box
Electronic Low-Voltage dimmers
INSTALLATION INSTRUCTIONS
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER
VARIOUS DIMMERS. REFER TO THE SPECIFIC DIMMER INSTRUCTIONS TO DETERMINE IF IT IS
COMPATIBLE WITH THIS MULTI-REMOTE
TM
. DO NOT USE A 3-WAY SWITCH IN PLACE OF THIS MULTI-
TM
REMOTE
.
ONLY DEVICES MARKED CO/ALR OR CU/AL.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
straight.
and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise
making sure that no bare conductor shows below the wire connectors. Secure each connector with
electrical tape.
in outlet box for dimmer. Mount dimmer into
Figure 1 – Multi-Remote Functions
box with mounting screws supplied.
Mounting Strap
Check for proper operation by pressing the
touch plate of the
Side Sections
TM
Multi-Remote
. Verify that the lights
connected to the dimmer turn ON and
operate properly (see To Operate
section). If the lights do not turn ON, go to
the Troubleshooting section. If the lights
turn ON, TURN OFF POWER and attach
®
Decora
wallplate.
INSTALLATION IS COMPLETE.
3/25/02, 11:53 AM
Upper
Rocker
Lower
Rocker

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Decora Multi-Remote MSE0R-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Leviton Decora Multi-Remote MSE0R-1

  • Page 1 Leviton is free of defects in materials 4. Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and workmanship under normal and proper use for two and, with circuit conductors, push firmly into appropriate wire connector.
  • Page 2 The color of this device can be changed to suit your interior design requirements. Simply obtain a color conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that wallplate must be removed). 1. Select the color of the face you desire.

Table of Contents