Download Print this page
Datalogic MC-P096 Quick Reference Manual

Datalogic MC-P096 Quick Reference Manual

Multi-slot battery charger

Advertisement

Quick Links

MC-P096 Multi-Slot Battery Charger
QUICK REFERENCE GUIDE
MC-P096 is a Multi-Slot Battery Charger (MBC) that allows you to charge the PowerScan™ PM9600 battery packs. MC-P096-M2 (Master) unit can
charge up to 2 batteries simultaneously and can be extended with maximum 4 MC-P096-E2 (Extension) units to charge up to 10 batteries.
Master unit has a power supply connector to power itself and the connected extension units. Moreover, Master unit has a USB Type-C connector for ser-
vice purposes and/or to retrieve information on battery packs.
MC-P096-M4 is a MBC configuration consisting of a MC-P096-M2 unit and a MC-P096-E2 unit to allow you to charge up to 4 batteries simultaneously.
MC-P096-M4
MBC CONFIGURATION
Master Unit
Extension Unit
MC-P096-M2 UNIT + 4 MC-P096-E2 UNITS
Maximum allowed configuration (4 extension units = 10 batteries)
Battery Charging
LED
820124600
Press to attach/detach
the slot
Removable Cover
Power-On LED
Rev. A
February 2022
WARNING: No more than 4 extension units can be supported.
USING MBC-P096
To attach or detach different units to each other, press on the tab indicated in the figure on the opposite page.
WARNING: Make sure that the Master unit is disconnected from the power supply before starting this operation.
POWER SUPPLY
Datalogic 12V, 5A wall adapter is recommended (90ACC0350) and a standard Power Cord cable is needed to connect the power supply to the socket, e.g.
the following Datalogic P/Ns:
P/N: 6003-0924 Power Cord, 220V, Italy/Chile
P/N: 6003-0941 US Power Cord, 110V, US, Standard
P/N: 6003-0940 Power Cord, AC, IEC/EU
CONNECTIONS
To power the MC-P096, follow the steps below:
1. Plug the power supply cable into the round connector placed on the Master unit;
2. Plug the power cord into the power supply unit;
3. Plug the power cord into a socket.
The Power LED turns on when the unit is correctly powered.
For battery data retrieving, follow the steps below:
1. Plug the USB Type-C cable into the USB port placed on the Master unit.
2. Plug the other side of the USB cable to a Host unit (e.g. a PC with Aladdin application).
CHARGE FUNCTION
Charging process starts automatically as soon as a battery pack is inserted into a free slot.
NOTE: It is recommended to use ONLY certified Datalogic P/N 70031180X Removable Battery Pack. Do not attempt to open and/or disassem-
ble the battery or the battery charger. To achieve the best performances, install and keep the MBC in a clean and cool environment.
Battery Charging State - LED Description
CHARGING LED STATE
Off
The LED is off if the slot is empty or, with the battery inside, in case of battery failure
Blinking:
Orange (charge <50%)
Charging
Green (charge >50%)
Solid Green
End of charge
The charge takes place slowly if the battery is extremely low.
NOTE: Not all types of battery failures can be signaled by the battery charger.
USB Type-C Cable (not provided in the box)
Cable for Service or retrieving Battery Packs'
information
Power Supply Unit
CHARGING STATE

Advertisement

loading

Summary of Contents for Datalogic MC-P096

  • Page 1 2 batteries simultaneously and can be extended with maximum 4 MC-P096-E2 (Extension) units to charge up to 10 batteries. Datalogic 12V, 5A wall adapter is recommended (90ACC0350) and a standard Power Cord cable is needed to connect the power supply to the socket, e.g.
  • Page 2 Red/Yellow/Green: Charging state 3.5h at 25 °C (77 °F) Power LED CAUTION: The Multi-Slot Battery Charger MC-P096 should be operated at an ambient temperature between 0 and 35 °C (32 to 95 °F) to Battery charging LEDs Battery charging LEDs achieve the maximum charging rate.

This manual is also suitable for:

Mc-p096-e2Mc-p096-m2Mc-p096-m4