Step
5
Disconnect the
connector [S70].
6
Unfasten the clamp of
the fan motor lead wire
(on the outer side of the
electrical box).
7
Release the fan motor
lead wire from the
groove and unfasten
the 2 hooks.
Removal Procedure
Procedure
Hook
Groove
[S70]: fan motor
[S70]
(R20911)
Fan motor lead wire
(R20913)
Outdoor Fan / Fan Motor
Points
Top view
Fan motor
lead wire
Clamp
(R20912)