Page 1
CleanTech 2000S / 4000S Boot Sanitizing Pan INSTALLATION AND OPERATION MANUAL...
Page 2
E-mail: service@meritech.com WARNING: The performance and effectiveness of CleanTech® systems have been extensively tested when using solutions provided by Meritech Systems, LLC. Satisfactory performance or effectiveness cannot be guaranteed when other solutions are used. FAILURE TO USE MERITECH SYSTEMS, LLC SUPPLIED...
Installation operation manual for set up and installation of those handwashing systems. The CleanTech 2000S w/ Boot Sanitizing Pan will fit into an area that accommodates 23" width X 42" depth footprint and will hook-up to your existing, standard hot/cold water lines and wall drain for the handwasher.
Overview The Meritech CleanTech 2000S & 4000S system with Boot Sanitizing Pan provides a means of washing hands and sanitizing boots at the same time for your employees. At the completion of every handwash cycle, the system replenishes the boot sanitizing pan with additional hard surface sanitizer to keep the PPM at a high, consistent level.
Facility Installation Instructions/Requirements The CleanTech 2000S system should be installed per the instructions within its separate installation / operation manual. This manual gives detailed instructions on the installation, operation, & cleaning of the Boot Sanitizing Pan. Do not hardwire the system electrical cord without having a way to disconnect the system from electrical source for future serviceability of the system.
Page 8
5. Take the water supply line and connect to the fitting on the bottom left side of the system. See photos below. Make certain the supply line is pushed at lease 3/8” – ½’ in to the fitting. 6. Take the opposite end of the supply line and attach it to the pan manifold. See photo on next page.
Page 9
7. Push the Boot Sanitizing Pan into the system, making certain the 2 tabs are on the inside legs of the CleanTech 2000S system. See Photo Below. 8. Once pan is in place make certain the 2 drain hoses are directed towards the floor drain, and that they are flat to prevent the pan from overflow ing.
Page 10
IF YOU SHOULD EXPERIENCE ANY DIFFICULTY OR ARE UNSURE ABOUT THE INSTALLATION PROCEDURE, WE ENCOURAGE YOU TO CONSULT IMMEDIATELY WITH MERITECH SYSTEMS, LLC. Meritech Systems, LLC 720 Corporate Circle, Suite K Golden, CO 80401 USA Phone: (800) 932-7707 Fax: (303) 790-4859 www.meritech.com...
First Time Start Up & Operation Once the CleanTech 2000S or 4000S system is installed with the Boot Sanitizing Pan(s) and are fully functional, follow the steps below to prime the pan for the first time and subsequently after each time the pan is cleaned.
The cleaning process should also be documented within your HAACP or SSOP procedures and/or per your company’s internal procedures. Meritech recommends daily cleaning of the system, as well as the Boot Sanitizing Pan. Please refer to the CleanTech Maintenance Manual or request the specific cleaning instructions from Meritech customer service.
10. Re-prime the pan per the instructions in this manual. 11. Inspect and clean water inlet fittings as needed. Contact Meritech Customer Service for additional assistance on cleaning assistance or instruction on any systems manufactured by Meritech. Contacting Meritech If you have questions about the general use of the CleanTech®...