Speed Measurement System; Table 26: Malfunctions Of The Speed Measurement System - ABB XAC19173 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A200-L
7 Troubleshooting / 7.5 Speed measurement system
7.5

Speed measurement system

Possible causes
No signal or
Assembly fault
poor signal
amplitude
present
Sensor defective
Measured
Contamination of
speed too
the sensor tip
high
Measured
- -
speed too
low
Other
- -
causes of
malfunction
Table 26: Malfunctions of the speed measurement system
© Copyright 2018 ABB. All rights reserved.
Remedy
The screw plug for the sensor is fitted with a gasket.
This gasket must be removed when the speed sensor is as-
sembled. If the gasket has been inadvertently fitted, the distance
of the sensor tip to the sealing disc giving the signal is increased.
This reduces the voltage amplitude of the speed signal which can
lead to problems with the evaluation electronics.
This problem will be remedied by removing the gasket.
Contact ABB Turbocharging Service Station
As the sensor tip is magnetic, it can attract material particles.
This reduces the distance to the auxiliary bearing, which can lead
to amplification of the noise component and therefore to false
triggering.
Dismantle the sensor, clean the sensor tip, and fit the sensor
back on with the specified tightening torque.
Contact ABB Turbocharging Service Station
If none of the measures described above remedy the malfunc-
tion, it is recommended to have the speed measurement system
checked by an ABB Turbocharging Service Station.
HZTL4036_EN
Revision L
May 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

A270-l59

Table of Contents