Operation Manual / 4 Product description / A200-L
5 Operation and service / 5.2 Service work
To prevent machine damage caused by ageing and downtime, we recommend having an in-
spection carried out by an ABB Turbocharging Service Station no later than 5 years after the
last service.
5.2.1
Service work every 25 ... 50 hours
CAUTION
Unknown operational changes
Impairment to the degree of a possible operating failure can be the con-
sequence.
Have any unknown causes clarified by an ABB Turbocharging Service Sta-
u
tion.
Visual check for air, exhaust gas, water and oil leaks.
u
Record operating data and enter in the engine logbook.
u
In case of deviations, determine the cause.
u
5.2.2
Service work at 100 hours after commissioning
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
u
gine is stopped.
5.2.3
Service work on turbocharger every 18000 hours
It is recommended to have this service work and these checks carried out by an ABB Tur-
bocharging Service Station. Damaged and worn out parts must be replaced with original
ABB parts.
Remove and clean the filter silencer and check for damage.
u
Dismantle the wall insert.
u
Check axial clearance A.
u
Clean compressor wheel, diffuser, wall insert and compressor casing and check for dam-
u
age.
Check the nozzle ring, turbine diffuser and turbine blades for any possible contamination,
u
damage or wear using a borescope.
This checking can also be carried out after disassembling the gas inlet casing.
Fit the wall insert.
u
Install the filter silencer.
u
© Copyright 2018 ABB. All rights reserved.