Intergas Heating Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council.
Note: This option only to be used in conduction with a Children, disabled, and elderly are at highest risk of being scalded. W-plan (Intergas cylinder sensor and 3-port valve) directly See instruction manual before setting temperature at water heater. wired to the boiler.
CONTROL PANEL AND READOUT The boiler has a fully integrated touch screen control panel and displays information about the operational mode of the boiler. Symbols (buttons), numbers, points and/or letters are displayed. ► The buttons on the display will light up as soon as they are operable and the lights will be extinguished when the buttons are no longer available.
Operational modes The boiler has a number of operational modes: The boiler is switched off. The boiler is switched off but is connected to the mains voltage. In this mode, the display view is characterized by: Boiler is switched off (mains voltage is present, however) ►...
Changing settings When the boiler is wired to a fuse spur and the mains voltage is present, the display will be turned on. From here, several settings can be set and/or modified. Switch the boiler on, if needed. However, to make/change these settings, it is not necessary to turn on the boiler.
Page 7
For the quick supply of domestic hot water, a DHW comfort function has been built in. This has the following settings: ► P-On The DHW comfort function is switched on within the chosen time blocks. The heat exchanger will maintain temperature during these time blocks.
To apply the clock program ► From a boiler that is in standby or in operational mode touch the control panel just above the power LED to access the main menu. ► Touch the Central Heating button. The current temperature of the central heating water is displayed in the left display.
FROST PROTECTION To prevent freezing of the condensation pipe, the boiler must be installed in a frost-free area. Where possible the condensate pipe must be installed internally in the property. The boiler is equipped with a frost protection which, as long as the mains voltage and gas supply are present, switches on the central heating pump and, if needed, the burner if the temperature of the heat exchanger drops too much.
FAULTS AND RESETTING If the following simple faults occur on the boiler, they can be solved as follows. The central heating system does not become hot or hot enough: ► Increase the set temperature of the room thermostat. ► Open the radiator valves. ►...
Page 12
All rights reserved. The information provided applies to the standard version of the product. Intergas Heating Ltd can therefore not be held liable for any damage ensuing from specifications that deviate from the standard version of the product. Although the available information has been composed with all possible care, Intergas Heating Ltd cannot be held liable for any errors in the information or for the consequences of such.