Network And Configuration Section; The Dip-Switch Features - Lab.gruppen FP+ Series FP 10000Q Operation Manual

Fp+ series dedicated touring amplifiers
Hide thumbs Also See for FP+ Series FP 10000Q:
Table of Contents

Advertisement

6 QUICK GUIDE OVERVIEW

6.2.1 Network and Configuration section

Four-channel model shown. Two-channel versions
have VPL and Bridge Mode switches for channels
A and B only. All models have different VPL values.
Functions are otherwise identical.
44dB
150V
41dB
121V
38dB
101V
35dB
32dB
83V
29dB
26dB
23dB

6.2.2 The dIP-switch features

The following features may be adjusted using the
DIP-switches on the rear panel of the amplifier.
Gain - Globally set for all channels, from +23 dB to +44
dB in 3 dB steps.
Option active - Not currently implemented.
fan Masked - When on, engages the intelligent
fan feature; fan speed is lowered when no signal is
present.
Bridge A+B and C+d- Switches the channel pairs
into bridge mode operation An automatic -6 dB gain
compensation is applied.
12 FP+ Series Operation Manual
70V
56V
47V
38V
VPL - The Voltage Peak Limiter provides optimum
peak voltage settings for each channel. Eight discrete
levels are selectable except on the FP 6000Q, which
has six levels.
fP 6000q
fP 7000
101 V
155 V
83 V
121 V
70 V
101 V
56 V
83 V
47 V
70 V
38 V
56 V
47 V
38 V
VPL in Bridge Mode
fP 6000q
fP 7000
202 V
310 V
166 V
242 V
140 V
202 V
112 V
166 V
94 V
140 V
76 V
112 V
94 V
76 V
Mode - Select VPL mode to either Hard or Soft
operation. For channels driving sub-woofers and
low-frequency drivers, it is recommended to use
the Hard setting for optimal operation. For mid- and
high- frequency drivers, always select Soft.
VPL
fP 10000q
fP 13000
150 V
195 V
121 V
170 V
101 V
140 V
83 V
116 V
70 V
100 V
56 V
80 V
47 V
66 V
38 V
54 V
fP 10000q
fP 13000
300 V
390 V
242 V
340 V
202 V
280 V
166 V
232 V
140 V
200 V
112 V
160 V
94 V
132 V
76 V
108 V

Advertisement