7 OPERATION AND PERFORMANCE
7.3.2 headroom, sensitivity and VPL / Gain
settings
The input amplifier and limiter system is designed
to accommodate extremes of performance. Typi-
cally, exceeding maximum input by much as +10 dB
will only result in a 1% increase in distortion. The
following schematics illustrate how the adjustable
VPL and Gain circuitry affect input sensitivity and
output power.
The tables to the left of the drawing below show input
sensitivity for a FP 13000 with a 2 ohm load and
195 Vpeak (max.) and 54 Vpeak (min.) respectively
for the eight different gain stages between +23 dB
and +44 dB. The resulting output power is displayed
in dBu, Vrms and watts in the tables to the far right.
Complete input sensitivity tables for all VPL and Gain
settings for all FP+ Series models can be found at
www.labgruppen.com.
Input Amplifier
Gain select switches
VPL set to 195 V
PEAK
Input
sensitivity
Gain set to:
(DIP-switches)
dBu / V
rms
1,0 / 0,87
+ 44 dB
4,0 / 1,23
+ 41 dB
7,0 / 1,7
+ 38 dB
10,0 / 2,5
+ 35 dB
13,0 / 3,5
+ 32 dB
16,0 / 4,9
+ 29 dB
19,0 / 6,9
+ 26 dB
22,0 / 9,8
+ 23 dB
VPL set to 54 V
PEAK
Input
Gain set to:
sensitivity
(DIP-switches)
dBu / V
rms
-10,1 / 0,24
+ 44 dB
-7,1 / 0,34
+ 41 dB
-4,1 / 0,5
+ 38 dB
-1,1 / 0,7
+ 35 dB
1,9 / 1,0
+ 32 dB
4,9 / 1,4
+ 29 dB
7,9 / 1,9
+ 26 dB
10,9, / 2,7
+ 23 dB
16 FP+ Series Operation Manual
fP 13000 VPL and GAIN settings
Level Control
Clip Limiter
Dynamic
Front panel
Gain reduction
potentiometer
+ 10 dB headroom to clip
relative to input sensitivity *)
Complete tables for all VPL
settings can be found at:
www.labgruppen.com
+ 16,1 dB headroom to clip
relative to input sensitivity*)
*) Headrom limited to +5dB at Gain set to +23 dB at Max. VPL
The headroom available through the input stage to
the clip limiter is shown by the dotted lines as +10
dB at 195 V peak and +16.1 dB at 54 V peak. These
lines illustrate the additional signal level that can be
accepted at the input before any significant distortion
will appear at the input stage.
If you use the level potentiometer in the
signal chain to reduce the level by an amount
greater than the headroom relative to input
sensitivity, AND you drive the amplifier
to clip level, you are in danger of clipping the input
stage before the current or voltage peak limiters are
activated.
When bridging two channels, you must
add +6 dB to the input sensitivity to achieve
maximum output voltage due to the
automatic -6 dB gain compensation
inserted by the amplifier.
Voltage Peak Limiter
VPL select switches
Hard/Soft switch
Voltage Clip sensing
Current clip sensing
Voltage Peak
Limiter set to:
(DIP-switches)
195 V
peak
170 V
peak
140 V
peak
116 V
peak
100 V
peak
80 V
peak
66 V
peak
54 V
peak
Output Power Amplifier
Class TD
Control Mute
Monitoring Level
Temperature
Fault/Warning
Output
Output Power
power
@ 2 Ohm
Watt
dBu / V
rms
45,0 / 138
6.500 W
43,8 / 120
6.500 W
42,1 / 99
4.970 W
40,5 / 82
3.540 W
39,2 / 71
2.550 W
37,3 / 57
1.850 W
35,6 / 47
1.330 W
33,9 / 38
960 W