Design Information; Product Dimensions And Clearances - Monogram UX12BS36PSS Installation Instructions Manual

30, 36 and 48 dual fuel professional ranges
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT DIMENSIONS AND CLEARANCES

48" Range Models
47-7/8"
Width
29 3/8" Depth
to Front of
Bullnose
35-1/4" to 36-3/4"
Height to trim.
Trim to be flush
or higher than
countertop.
28-1/2" Depth
to Front of Door
WARNING
A suitable overhead vent
hood is required for model ZDP484. Installations
without a hood require 48" minimum to
combustibles. A custom hood installation
with exposed horizontal combustible surfaces
must have an Auto-On feature. Refer to hood
installation instructions for specific hood
clearances.
The surface of the entire back wall above the
range and below the hood must be covered
with a non-combustible material such as metal,
ceramic tile, brick, marble or other stone.
CAUTION
To prevent drafts from
affecting burner operation, seal all openings
in floor under appliance and behind appliance
wall.
** A s defined in the National Fuel Gas Code (ANSI
Z223.1/CSA B149.1, Current Edition). Clearances from
non-combustible materials are not part of the ANSI
Z21.1/CSA 1.1 scope and are not certified by CSA.
Clearances less than 12" must be approved by local
codes and/or the authority having jurisdiction.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall on
each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and the
bottom of the wall cabinet.
For island installation, maintain 2-1/2 in. minimum from
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
31-2000667 Rev. 1

Design Information

1"
Countertop
to Cooking
Surface
3-1/4"
to 4-3/4"
Toekick/
leg Height
16"
Max.
60" for ZDP486
minimum to
combustibles
Universal Utility Locations
8"
14"
Gas/
6-1/2"
Electric
48" Minimum
Vent Hood
Required for
Model ZDP484
Non-
Combustible
Material **
12"
Minimum
Each Side
48" Min.
Back
2-1/2" Min.
3" Min.
Island
Cutout
Top View
16"
Electric
2"
2"
48"
12" Minimum
to Adjacent Wall
18"
Min.
3" Min.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ux12bs48pssUxadbs36pssUxadbs48pss