E: 23. Combination Error (Outdoor Unit) - Fujitsu ABYG54KRTA Service Manual

Ceiling type air conditioner
Table of Contents

Advertisement

2-6. E: 23. Combination error (Outdoor unit)

Wired remote
Indicator
controller
Detective actuator
Indoor unit
Forecast of cause
Check point 1. Check the type of indoor unit
Check the type of the connected indoor unit.
-> If there is an abnormal condition, correct it by refer to the installation manual or the "DESIGN
& TECHNICAL MANAL".
Check point 2. Replace the main PCB
If check point 1 do not improve the symptom, replace the main PCB of the outdoor unit.
2-6. E: 23. Combination error (Outdoor unit)
Error code
End
The outdoor unit receives the serial signal of applied
refrigerant information from indoor unit.
Incorrect indoor unit is selected.
- (03-12) -
E: 23
2. Troubleshooting with error code

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoyg54krta