10. Installation
CAUTION
• Select the power cable in accordance with relevant local and
national regulations.
• Wire size must comply with local and national code.
• For the power cable, use the grade of H07RN-F or H05RN-F
materials.
• You should connect the power cable into the power cable terminal
and fasten it with a clamp.
• The unbalanced power must be maintained within 10% of supply
rating among whole indoor units.
• If the power is unbalanced greatly, it may shorten the life of the
condenser. If the unbalanced power is exceeded over 10% of supply
rating, the indoor unit is protected, stopped and the error mode
indicates.
• To protect the product from water and possible shock, you should
keep the power cable and the connection cord of the indoor and
outdoor units in the iron pipe.
• Connect the power cable to the auxiliary circuit breaker. An all pole
disconnection from the power supply must be incorporated in the
fixed wiring(≥3mm).
Setting an indoor unit address and installation
option
Set the indoor unit address and installation option with remote
control option. Set the each option separately since you cannot
set the ADDRESS setting and indoor unit installation setting
option at the same time. You need to set twice when setting
indoor unit address and installation option.
Option setting procedure
Power
Temperature
Options
Timer
Direction
20
1 Remove batteries from the remote control.
2 Insert batteries and enter the option setting mode while
pressing
3 Check if you have entered the option setting status.
4 After entering the option setting status, select the option.
CAUTION
• Option setting is available from SEG1 to SEG 24
• SEG1, SEG7, SEG13, SEG19 are not set as page option.
• Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18,
SEG20~24 as OFF status.
SEG1
0
SEG7
1
SEG13
2
SEG19
3
Air flow direction
(Up and down)
Mode
Fan speed
Air flow direction
(Left and right)
Settings
SET
(High Temp button) and
SEG2
SEG3
SEG4
X
X
SEG8
SEG9
SEG10
X
X
SEG14
SEG15
SEG16
X
X
SEG20
SEG21
SEG22
X
X
On (SEG1~12)
(Low Temp button).
SEG5
SEG6
X
X
X
SEG11
SEG12
X
X
X
SEG17
SEG18
X
X
X
SEG23
SEG24
X
X
X
Off (SEG13~24)

Advertisement

Table of Contents
loading

Table of Contents