  • Page 1 ULTRA SIO-104 User Manual | 3550 © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 2: Table Of Contents

    APPENDIX B – HOW TO GET ASSISTANCE ..................... 17 APPENDIX C – ELECTRICAL INTERFACE ......................18 APPENDIX D – PC/104 ............................19 APPENDIX E – SILK SCREEN ..........................20 WARRANTY ................................ 21 ....................................© Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 3: Introduction

    The ULTRA SIO-104 provides a single field selectable port configurable as RS-422/485 supporting asynchronous data rates up to 460.8K bps. The ULTRA SIO-104 utilizes the Exar 16C850, which provides 128-byte, transmit and receive FIFOs. These larger buffers allow error free operation even in high-speed applications.
  • Page 4: Before You Get Started

    Before You Get Started What’s Included The ULTRA SIO-104 is shipped with the following items. If any of these items is missing or damaged, please contact Sealevel for replacement. • ULTRA SIO-104 Adapter • Nylon Mounting Hardware Kit (PC304-NK) Advisory Conventions...
  • Page 5: Card Setup

    Sony (or compatible) 207M "9 Pin" connector. Card Setup The ULTRA SIO-104 contains several jumper straps for each port, which must be set for proper operation. Address Selection The ULTRA SIO-104 occupies eight consecutive I/O locations. A DIP-switch is used to set the base address for these locations.
  • Page 6 Port Enable / Disable The port on the ULTRA SIO-104 can be enabled or disabled with switch position 8 on the DIP-switch. The port is enabled with the switch “On” or “Closed” and disabled when “Off” or “Open” (refer to Figure 2). If the port is disabled, be sure to also disable the interrupt request for that port by removing the IRQ jumper at header J2.
  • Page 7 Some communication software packages refer to RS-485 as RTS enable or RTS block mode transfer. One of the unique features of the ULTRA SIO-104 is the ability to be RS-485 compatible without the need for special software or drivers. This ability is especially useful in Windows, Windows NT, and OS/2 environments where the lower level I/O control is abstracted from the application program.
  • Page 8 Figure 6 - Header E4, RS-485 'Auto Enabled, with 'Echo' Figure 7 - Header E4, RS-485 'RTS' Enabled, with ‘No Echo’ Figure 8 - Header E4, RS-485 'RTS' Enabled, with 'Echo' © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 9 Adds or removes the 120-ohm termination. Connects the TX+ to RX+ for RS-485 two-wire operation. Connects the TX- to RX- for RS-485 two-wire operation. Figure 10 - Headers E3, Line Termination © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 10 Figure 11 - Clocking Mode 'Divide By 4' To select the maximum data rate (460.8K bps) place the jumper in the divide by 1 (silk-screen DIV1) position. Figure 12 - Clocking Mode 'Divide By 1' © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 11 If your communications package allows the use of Baud rate divisors, choose the appropriate divisor from the following table: For this Data Rate Choose this Divisor 1200 bps 2400 bps 4800 bps 9600 bps 19.2K bps 38.4K bps 57.6K bps 115.2K bps 230.4K bps 460.8K bps © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 12: Software Installation

    Only users running Windows 7 or newer should utilize these instructions for accessing and installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing support@sealevel.com...
  • Page 13: Physical Installation

    Friday. For email support contact: support@sealevel.com. Physical Installation Extreme care should be taken when installing the ULTRA SIO-104 to avoid causing damage to the connectors. After the adapter is installed, connect your I/O cable to J1. Please note these headers are keyed so that pin 1 of the cable matches pin 1 of the connector.
  • Page 14: Technical Description

    Technical Description The ULTRA SIO-104 provides the ultimate RS-422/485 serial connection for your PC/104 application. The ULTRA SIO-104 utilizes the 16850 UART. These chip features programmable baud rates, data format, interrupt control and 128-Byte input and output FIFOs. Features Selectable interrupts (IRQs) 3, 4, 5, 7, 9, 10, 11, 12, 15 •...
  • Page 15: Specifications

    10 to 90% R.H. Non-Condensing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested. These printed circuit boards are solder mask over bare copper or solder mask over tin nickel. Power Requirements...
  • Page 16: Appendix A - Troubleshooting

    No two adapters can occupy the same I/O address. Make sure the Sealevel Systems adapter is using a unique IRQ. While the Sealevel Systems adapter does allow the sharing of IRQs, many other adapters (i.e., SCSI adapters & on-board serial ports) do not.
  • Page 17: Appendix B - How To Get Assistance

    If possible, please have the adapter installed in a computer ready to run diagnostics. 3. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
  • Page 18: Appendix C - Electrical Interface

    (Tx+ to Rx+ and Tx- to Rx-). Four wire mode allows full duplex data transfers. RS-485 does not define a connector pin-out or a set of modem control signals. RS-485 does not define a physical connector. © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 19: Appendix D - Pc/104

    Minimizing component count and power consumption (typically 1-2 Watts per module) by • reducing required bus drive on most signals to 4 mA. Sealevel Systems has been a member of the PC/104 Consortium since its inception. Questions about the PC/104 Consortium can be sent to: PC/104 Consortium P.
  • Page 20: Appendix E - Silk Screen

    Appendix E – Silk Screen © Sealevel Systems, Inc. 3550 Manual | SL9121 9/2022...
  • Page 21: Warranty

    Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn-in and testing.