Crystal Vision ADC104 User Manual

Analogue to digital converters

Advertisement

Quick Links

ADC104
Analogue to digital converters
Crystal Vision Ltd., Lion Technology Park, Station Road East, Whittlesford, Cambridge, CB22 4WL, England.
E-mail: sales@crystalvision.tv
Website: www.crystalvision.tv
Tel: +44(0) 1223 497049
Fax: +44(0) 1223 497059

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADC104 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crystal Vision ADC104

  • Page 1 ADC104 Analogue to digital converters Crystal Vision Ltd., Lion Technology Park, Station Road East, Whittlesford, Cambridge, CB22 4WL, England. E-mail: sales@crystalvision.tv Website: www.crystalvision.tv Tel: +44(0) 1223 497049 Fax: +44(0) 1223 497059...
  • Page 2: Table Of Contents

    ADC104F controls ADC104FK controls ADC104N controls 3 Using the active control panel 3.1 Navigating the display Updating the display 3.2 The ADC104 menu structure Selecting time options Selecting control options Selecting test patterns Using the status display 4 Card edge operation 4.1 Card edge controls...
  • Page 3 Crystal Vision ADC104OperationalManualV3_2 RM01 RM02 RM18 5.2 Configuring external controls GPI control assignment Configuring a second serial port 5.3 GPI connections FR2AV GPI Connections FR1-6 GPI Connections FR2-12 GPI Connections FR2-8 GPI Connections DTBAV and DTB-2 GPI connections 5.4 Setting the line standard selection 5.5 Setting Ext sync options...
  • Page 4: Introduction

    Crystal Vision Introduction Introduction The ADC104 series of 10-bit analogue to digital converters are designed to convert RGBS/YUVS signals to SDI serial digital video. The range consists of the ADC104F which fully meets ITU 601 specifications for component video filtering, the ADC104N which nearly meets the ITU 601 specification and the ADC104FK, designed for use with graphics keys and which accepts only a Y and sync input.
  • Page 5: Using Chroma Levels

    Rear connector options The ADC104 is a single height module and will fit into all Crystal Vision rack frames. Three rear connectors are available, the RM01 providing two outputs, the RM02 providing three outputs plus a sync loop-through output and the RM18 which provides four outputs and a sync loop-through output.
  • Page 6: Using Statesman

    Obey any installation program prompts and restart the PC when prompted Running Statesman for the first time Statesman may be run from the Crystal Vision programs folder via the Start menu or by double-clicking on the Statesman.exe file in the installed program directory (default is C:\Program Files\CrystalVision).
  • Page 7: Statesman Operation

    Ensure that DIL lever 10 is set for in the DOWN position for Statesman control. A Warning: message will appear to indicate that Statesman controls may be overridden by the card edge if the ADC104 is set to local mode (DIL lever 10 UP) Page 6 19/09/05...
  • Page 8: Adc104F Controls

    Crystal Vision Using Statesman ADC104F controls The following controls are available: • H Pos slider: adjust horizontal position of SDI output picture from 30 pixels to –30 pixels (+/- 2µs) • Sync: Y sync/Ext – use syncs on green/luminance or external analogue syncs •...
  • Page 9: Adc104Fk Controls

    Crystal Vision ADC104OperationalManualV3_2 ADC104FK controls The following controls are available: • H Pos slider: adjust horizontal position of SDI output picture from 30 pixels to –30 pixels (+/- 2µs) • Sync: Y sync/Ext – use syncs on green/luminance or external analogue syncs •...
  • Page 10: Adc104N Controls

    Crystal Vision Using Statesman ADC104N controls The following controls are available: • H Pos slider: adjust horizontal position of SDI output picture from 30 pixels to –30 pixels (+/- 2µs) • Sync: Y sync/Ext – use syncs on green/luminance or external analogue syncs •...
  • Page 11: Using The Active Control Panel

    ADC104OperationalManualV3_2 Using the active control panel The Crystal Vision active control panel is available as an integral part of the FP2-LF front door for the FR2AV 2U frame, the FR1AV frame, and the DTBAV desktop box or as a remote panel. Only one control panel can be connected to any frame, although one panel can control two frames.
  • Page 12: Navigating The Display

    When the desired module is selected press the ENTER key to access that module’s HOME menu. The ADC104 home menu Ensure that DIL lever 10 is set for remote control (DOWN) to use the front control panel. Note: 3.1 Navigating the display...
  • Page 13: Updating The Display

    If necessary, use the upward arrow to leave and then re-enter a menu to update the display. 3.2 The ADC104 menu structure The main top-level menus for a module are obtained by pressing the F1, F2, F3 and F4 keys from that module’s HOME menu.
  • Page 14: Selecting Time Options

    Crystal Vision Using the active control panel Selecting time options The Time menu provides access to the following options: • Adjust horizontal position of SDI output picture from 30 pixels to –30 pixels (+/- 2µs) • Use syncs on green/luminance or external analogue syncs •...
  • Page 15: Selecting Test Patterns

    The status display provides the following information: The status menu Description The ADC104 status display shows the presence of the selected reference sync along with the video input standard which may be 525L or 625L. The input standard will only be auto-detected if Jumper J2 is in the AUTO position –...
  • Page 16: Card Edge Operation

    Crystal Vision Card edge operation Card edge operation Although, the ADC104 may be operated through a remote interface such as the Active Control Panel or Statesman, all functions can be accessed using card edge controls. 4.1 Card edge controls The front edge of the card provides LED status and power rail monitoring, menu selection, rotary set-up control and a ten-way DIL menu selector.
  • Page 17: Setting Control Options

    Crystal Vision ADC104OperationalManualV3_2 Setting control options Select the control method with the DIL switch as follows: Lever Label Description Up selects an RGB input, down selects a YUV input Up selects sync input on Y/Green, down selects sync on the external input...
  • Page 18 Crystal Vision Card edge operation Using split screen test signals The eight test signals (not ADC104N) may be displayed in split-screen mode (TPat DOWN) whilst adjusting the horizontal picture position (Hpos DOWN). Function Notes Tpat Hpos Normal Eight full-screen and split-...
  • Page 19: Installation

    ADC104OperationalManualV3_2 Installation The ADC104 series of analogue component to SDI converters are single height modules, which will fit into all Crystal Vision rack frames. The FR2AV 2U frame will accommodate up to 12 single height Crystal Vision modules and six single height modules will fit in the FR1AV 1U frame.
  • Page 20: Rm02

    Crystal Vision Installation RM02 FR2AV RM02 rear connectors Description RM02 (ZLA00128 artwork) • 9 modules per FR2AV frame • 3 modules per rear connector • 9 connections available • Card 1 fits in slots 1, 5 and 9 • Card 2 fits in slots 2, 6 and 10 •...
  • Page 21: Rm18

    Crystal Vision ADC104OperationalManualV3_2 RM18 RM18 fits in FR2AV, FR1AV & DTBAV frames Description RM18 (ZLA00175 artwork) • 6 modules per FR2AV frame, 3 per FR1AV, 1 per DTBAV • 1 module per rear connector • 10 connections available • Card fits in upper slot •...
  • Page 22: Configuring External Controls

    DOWN GPI control assignment The ADC104 provides 6 GPI lines ‘a’ to ‘f’ which are assigned functions similar to some of the levers on the 10 way piano switch. GPI configuration jumpers J4 to J9 control the function of the available GPIs.
  • Page 23: Configuring A Second Serial Port

    Output RS422 Tx- The RS422 connections to the ADC104 card is accessed via the Remote 1 connector on FR1-6 or FR1AV frame, Remote 1 or Remote 3 connector on a FR2-12 or FR2AV frame and by the 15way Remote connector of the DTB-2 or DTB-AV frame.
  • Page 24: Gpi Connections

    Crystal Vision Installation 5.3 GPI connections Each slot has an associated set of connections on the frame rear-panel remote connectors. For convenience, GPI lines are associated with reference codes ‘a’ to ‘f’ in the connector pin-out tables for each frame.
  • Page 25: Fr2-12 Gpi Connections

    Crystal Vision ADC104OperationalManualV3_2 FR2-12 GPI Connections Slot no. ‘a’ pin ‘b’ pin ‘c’ pin ‘d’ pin ‘e’ pin ‘f’ pin 8 (1) 9 (1) 18 (1) 26 (1) 19 (2) 20 (2) 7 (1) 16 (1) 17 (1) 25 (1)
  • Page 26: Setting The Line Standard Selection

    5.4 Setting the line standard selection The 625 / 525 line selection is controlled by jumper links J2 and J3 at the top right of the module. ADC104 line standard jumpers The following table describes the jumper positions required: Setting...
  • Page 27: Setting Node Addresses

    The two ranges are provided to allow one control panel to control two frames. ADC104 Node Address jumper/selector S1 is normally set to position 0 (factory default). If the ADC104 card is used in older frames such as FR2-12 or FR1-6 and these frames are being used with an active front panel then the Hex switch S1 can be used to set the node number (0 to 15) of the card.
  • Page 28: Jumper Setting Summary

    Used to select node address in older frames (default position 2-3) On no account should factory set jumpers be moved from their default positions, unless WARNING! guided to do so in this manual or by Crystal Vision support personnel. 18/02/03 Page 27...
  • Page 29: Problem Solving

    Crystal Vision ADC104OperationalManualV3_2 Problem solving 6.1 Card edge LEDs The front edge of the card provides LED status and power rail monitoring, rotary set-up controls and a ten-way DIL menu selection switch. The ADC104F front view The following table summarises the card edge LED functions and colours:...
  • Page 30 Crystal Vision Problem solving Basic fault finding guide The Power OK LEDs are not illuminated Check that the frame PSU is powered and that the frame PSU is functioning – refer to the appropriate frame manual for detailed information. There is no video output Check that valid component inputs are present and that any cabling is intact.
  • Page 31: Specification

    Crystal Vision ADC104OperationalManualV3_2 Specification General Dimensions 100mm x 266 mm module with DIN 41612 connector Weight 220g Power consumption 5.0 W Inputs Analogue Input YUV and syncs or RGB and syncs 700mV into 75ohm. (Y and Green 1 volt with syncs) External syncs input can be composite Black &...
  • Page 32 Crystal Vision Specification Noise <-60dB weighted luminance or chrominance (ADC104F/N); <-60dB weighted (ADC104FK) Gain Error <1% RGB matrix error <1% Chroma/Luma delay <5ns (applies to ADC104F/N only) inequality Sampling Sampled to 10 bit precision at 13.5MHz on Y and (ADC104F/N only) 6.75MHz on U and V...
  • Page 33 FR1AV 1U frame for up to 6 Crystal Vision modules DTB-AV Desk top box for up to 2 Crystal Vision modules RM01 Single slot frame rear module. Allows maximum number of ADCs in frame (12 in 2U, six in 1U, two in desk top box). Gives access to two SDI...

Table of Contents