Adjusting VBI and test pattern options 3 Using the active control panel Selecting the ENC116 Navigating the display Updating the display 3.1 The ENC116 menu structure Menu numbering scheme 3.2 Adjusting signal timing 3.3 Setting Chroma and burst phase 3.4 Adjusting signal gains and offsets Adjusting Y/C gain 3.5 Setting advanced options...
Page 3
Crystal Vision ENC116 User Manual V4.2 4.3 Display software version and node address 4.4 Adjusting signal timing 4.5 Adjusting signal gain and offsets 4.6 Recalling factory gain settings 4.7 Recalling all factory settings 4.8 Setting output options 4.9 Setting reference options 4.10 Setting VBI options...
Introduction 1 Introduction The ENC116 is a 10-bit broadcast quality Serial Digital to Analogue Composite converter. It accepts either 625 or 525 line input, with automatic detection. There is one reclocked serial digital output and six analogue PAL/NTSC outputs. The available outputs depend on the rear module used.
Frame packing density The ENC116 is a 100mm x 266mm module, which fits in the three standard frames and can be integrated with any boards from the company’s full product range. It may be used with the single slot RM01 and RM23 rear connectors, the double slot RM18 rear connector and the quadruple slot RM02 rear connector.
Running Statesman for the first time The Statesman PC Control System may be run from the Crystal Vision programs folder via the Start menu or by double-clicking on the Crystal Vision.exe file in the installed program directory. When the program runs it will require licence information and an administrator name and password.
Always ensure that the active front panel (if fitted) is in STATESMAN mode. If the front panel is active, control via Statesman will be subject to high latency and the response to changes will be slow. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
If there are no SDI or reference inputs the output will be black & burst (or test patterns if selected). Status Input, reference presence and standard are shown along with FIFO and Genlock status. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
In PAL this control provides a ± 2° ScH to Chroma phase offset. CAL button zeros the current setting. Status Input and reference presence is shown along with FIFO and Genlock status. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Slider varies burst gain in 0.1% steps from 70 to 130% of nominal. CAL button clears the current setting to 100%. Status Input and reference presence is shown along with FIFO and Genlock status. Cal Gains All sliders are returned to their default positions. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
CAL button selects First Active Line as 22/335 for PAL or 20/282 for NTSC. Output selection Selects video output from incoming Serial Digital Video, modulated ramp, EBU bars or 100% bars. Status Input and reference presence is shown along with FIFO and Genlock status. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
At power up, the two line 20-character screen will display ‘Crystal Vision’ followed by the firmware version number for the control panel. All eight control panel keys LEDs will illuminate.
Card edge DIL switch lever 2 must be DOWN and Jumper links J8 and J9 MUST be set Note: to ‘422’ to enable an active front panel control in a Crystal Vision Frame. Refer to Installation Chapter for serial port settings.
Device menu • Rotary control – shaft encoder used to select options or variable data Please refer to the Crystal Vision Control Panel manual for details of the Panel Setup, Note: Lock Panel and Diagnostic menus. Updating the display The values displayed on an active front panel are only updated when an adjustment is made and when changing menu level.
Gain (Level and offset) – press F3 • Misc. (Calibrate, Blanking, Test Patterns, and Status) – press F4 The following chart shows the available ENC116 menus. The ENC116 menu tree Function keys and shaft encoder LEDs are illuminated when active.
Shaft encoder adjusts delay from –4µs to 1 line in pixel steps. CAL button zeros the current setting. Sub-pixel delay Shaft encoder adjusts delay from 0 to 1 pixels in 1/32 pixel (2ns) steps. CAL button zeros the current setting. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
In NTSC shaft encoder adds ScH to Chroma phase offset from 0° to 360° in 1/16° steps. In PAL this control provides a ± 2° ScH to Chroma phase offset. CAL button zeros the current setting. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
0.3 IRE steps from –22 IRE to +22 IRE. CAL button clears the current setting to +7.5 IRE. Y/C Gain Use the F keys to select the required Y/C sub-menu (described in the next section). 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
CAL button clears the current setting to 100%. V gain Shaft encoder varies V gain in 0.1% steps from 0 to 130% of nominal. CAL button clears the current setting to 100%. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Use the F keys to select the required sub-menu (described in the next section). Choose Serial Digital Input if black and burst should be output when the input signal is Note: absent. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Shaft encoder varies First Active Line (end of VBI). PAL lines 6 - 22 and 320 – 335 or NTSC lines 10 – 20 and 273 – 282 when VBI lines are unblanked. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
The front edge of the card provides LED status and power rail monitoring, menu selection, rotary set-up controls and a ten-digit visual status display. The ENC116 front view In general the four position DIL switch changes mode or options whilst the rotary SELECT control is used to select one of the configuration menus and the rotary ADJ control is used to assign values to configuration variables.
Varies U & V gains simultaneously. U gain Ugn nnn.n% Varies Cb gain from 0 to 180% in 0.1% steps. V gain Vgn nnn.n% Varies Cr gain from 0 to 130% in 0.1% steps. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Menu Display Text Function Clear gain Clear gain Clears all user adjustable gains – returns ENC116 to factory gain settings. Clear done ENC116 gains returned to factory defaults. Clear gain ignores DIL switch position 1 (CAL). Note: 4.7 Recalling all factory settings...
525-line input. Time-Base Corrector is OK. SDInnnlate Time-Base Corrector out of range – Serial Digital input is nnn lines after Reference Sync input. Refer to Trouble shooting chapter for help with optimising TBC range timing. Note: 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Crystal Vision Hardware installation 5 Hardware installation The ENC116 encoder fits into all Crystal Vision rack frames. All modules can be plugged in and removed while the frame is powered without damage. 5.1 Universal rear connectors Up to twelve single height modules may be fitted in a 2U Indigo frame depending on the choice of rear connector.
Placing J1 in the 75Ω position does not remove the sync loop through on the RM23. This Note: rear connector allows loop through syncs to remain even when the ENC116 is removed since the loop-through is actually on the RM23 rear connector itself.
RM02 ZLA00128 Three ENC116 cards can be fitted the RM02 rear modules. Card 1 fits in the top position, Note: card 2 in the second from the top and card 3 fits in the bottom. No card is fitted in the 3rd slot position.
2 and +5V @500mA is pin 1 in each case. Remote 2 and Remote 4 are 26 way high density ‘D’ type male plugs and frame ground is pin 6 and +5V @500mA is pin 15 in each case. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
GPI functions. Jumpers J6 to J9 determine if the serial communication is RS422 or RS232. The GPI/Serial link jumpers on the ENC116 SDI Encoder Control lines ‘a’ to ‘d’ can be used to provide RS422 communication whilst ‘e’ and ‘f’...
Page 31
The standard remote control port settings are as follows: Baud Rate 19k2 Parity None Data Bits Stop Bits Hand shaking None Other standards are available on request. Please contact factory for remote protocol 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
*J1 should be in the LOOP position on the RM23 to avoid double terminating the sync Note: input. Output and reference jumper links J1 to J5 are near the edge connector 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
SW1 is a board level reset switch used when testing the board and is not accessible in a normal installation. Refer to the Problem Solving chapter for help with re-setting the card. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
TBC is out of range - Sync input is greater than 10 lines before or 10 lines after SDI. When the time-base corrector is out of range, output timing may be automatically Note: adjusted by approx. 0.5µs to prevent picture disturbance. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Card edge or active control panel settings may have overridden Statesman settings if they were accessed more recently Active control panel does not work as expected Check that the REM DIL lever is DOWN 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Page 36
This is to avoid double terminating the sync input. Placing J1 in the 75Ω position does not remove the sync loop through on the RM23. This rear connector allows loop through syncs to remain even when the ENC116 is removed since the loop-through is actually on the RM23 rear connector itself.
273-282. PAL lines 6 or 319 may also be blanked by menu selection. Delay Reference input to composite output: -4µs to 4.9 lines. For zero delay, serial video input must be 4.3µs before output. 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Page 38
Statesman enabled only 2U frame for up to 12 modules Indigo 1S Statesman enabled only 1U frame for up to 6 modules Indigo DTS Statesman enabled only 1U Desk top box for up to 2 modules 29/09/06 ENC116 User Manual V4.2 ENC116V4 Operational Manual V4_2...
Need help?
Do you have a question about the ENC116 and is the answer not in the manual?