King Pigeon D225 User Manual

King Pigeon D225 User Manual

Plc data acquisition protocol conversion gateway
Table of Contents

Advertisement

Quick Links

PLC data acquisition protocol conversion gateway
D225
D225
User manual
Version:
V1.2
Date:
7th,DEC.2020
Copyright:
Shenzhen King
Pigeon H-TECH Co.,LTD.
website
:www.4g-iot.com

Advertisement

Table of Contents
loading

Summary of Contents for King Pigeon D225

  • Page 1 PLC data acquisition protocol conversion gateway D225 D225 User manual Version: V1.2 Date: 7th,DEC.2020 Copyright: Shenzhen King Pigeon H-TECH Co.,LTD. website :www.4g-iot.com...
  • Page 2 PLC Data acquisition protocol conversion gateway -D225 Perface Thank you for using the PLC data acquisition protocol conversion gateway D225 of Shenzhen King Pigeon Hi-Tech Co., Ltd. Reading this product manual will enable you to quickly grasp the functions and usage of this product.
  • Page 3: Table Of Contents

    4.2.3 Serial Port Configuration ..................18 4.2.4 Protocol Parameter ..................... 19 4.2.5 Server Configuration ................... 20 D225 Application case ......................21 Data acquisition of Mitsubishi PLC ................21 5.1.1 FX3Uand D225 device connection............... 22 5.1.2 Configuration Software Configuration ..............23 5.1.3...
  • Page 4 5.1.3.2 The data configuration of collecting FX3U output Y is as follows: collecting Y0- Y7………………………………………….................... 25 5.1.3.3 The communication connection configuration with D225 is as folows ..26 5.1.3.4 Comarison of the data collected by Modbus Poll and the data checked by the programming software .......................
  • Page 5 PLC Data acquisition protocol conversion gateway -D225 Mapping address corresponding to DL/T645-1997 protocol meter ........54 Mapping address corresponding to DL/T645-2007 protocol meter ........56 Shenzhen King Pigeon Hi-Tech Co.,LED Pages 5 Total 58 Ver 1.2...
  • Page 6: Product Introduction

    The PLC data acquisition protocol conversion gateway D225 is a converter used to convert the main PLC data acquisition protocol on the market into Modbus TCP protocol. D225 can store the PLC I/O point data to the gateway through the RS-232 or RS-485 serial port of the PLC. The gateway transmits the data to the cloud platform through the Modbus protocol.
  • Page 7: Packing List

    PLC Data acquisition protocol conversion gateway -D225 Packing list Before installing and using the D225 device, please confirm whether the following materials are in the product box  1x D225 device  1x 2 bit 3.5 female connector for input power ...
  • Page 8 1 x QR code label (including User manual download and software information) Remark:If the above items are missing or damaged,pls kindly contact sales respresentive of King Pigeon. Optional accessories (must be purchased separately)  35mm DIN Rail installation kit Shenzhen King Pigeon Hi-Tech Co.,LED Pages 8 Total 58 Ver 1.2...
  • Page 9: Function Features

    1 x RJ45,10Mbps specification Network interface Ethernet ESD connection:8KV ,surge:4KV(10/1000us) protection Serial QTY 1 x RS232、1 x RS485、1 x TTL Serial port Serial Port 4800bps-128000bps baud rate data bit 7,8,9 Shenzhen King Pigeon Hi-Tech Co.,LED Pages 9 Total 58 Ver 1.2...
  • Page 10 IEC 61000-4-6 (CS)Level 4 IEC 61000-4-8 (M/S) Level 4 other CE、FCC、ROHS、3C Working -45~85℃,5~95% RH Tem.&Hum. Environment Storage -45~105℃,5~95% RH Tem.&Hum. Housing Metal materials Size 9.6cm×6.8cm×2.5cm(L*W*H) IP30 Other 260g Installation Wall-mounted、Rail type Method Shenzhen King Pigeon Hi-Tech Co.,LED Pages 10 Total 58 Ver 1.2...
  • Page 11: Hardware

    PLC Data acquisition protocol conversion gateway -D225 2 Hardware Dimensions unit: mm Side view left Side view right Front view Bottom view Bottom view Top view Shenzhen King Pigeon Hi-Tech Co.,LED Pages 11 Total 58 Ver 1.2...
  • Page 12: Led Indicator

    RS485/RS232 have data transmission RS485/RS232 No lighting RS485/RS232 no data transmission Interface definition 2.3.1 RJ45 Pin definition Network interface Definition 568B Definition Description Orange white Send positive Orange Send negative Shenzhen King Pigeon Hi-Tech Co.,LED Pages 12 Total 58 Ver 1.2...
  • Page 13: Rs-485、Ttl And Power Supply Pin Connector

    Receiver Public land Power input - Power input + 2.3.3 RS232 Pin definition RS232 Description DB9 NO Function Description Receive data(RXD) Send data(TXD) RESET Signal land(GND) RESET Reset button Shenzhen King Pigeon Hi-Tech Co.,LED Pages 13 Total 58 Ver 1.2...
  • Page 14: Device Installation

    Remark:If the PC is connected for the first time, because the factory IP of the D225 device is 192.168.1.250, you need to change the computer IP to 192.168.1.* to search for the device. That is the device and the computer must be in the same network segment.
  • Page 15: Search Device

    4.1.3 Connect Device Double-click the device you want to configure, a prompt box "read successfully" appears, click OK to enter the device configuration interface Shenzhen King Pigeon Hi-Tech Co.,LED Pages 15 Total 58 Ver 1.2...
  • Page 16: Configuration Software Configuration Instructions

    Device search Search all D225 devices in the same LAN Read Settings Read the configuration parameters of the logged-in D225 device Click this button to save all configuration parameters to the device. The Save Settings device must be restarted for the modified configuration to take effect Restart Click reset button,reset device...
  • Page 17: Description Of Network Configuration Of This Device

    IP address of this device yourself according to the IP address distribution in the LAN. 2、[IP Mode] Select "Dynamic" to automatically obtain an IP address in the LAN only when the router in the LAN allows dynamic allocation of IP addresses. Shenzhen King Pigeon Hi-Tech Co.,LED Pages 17 Total 58 Ver 1.2...
  • Page 18: Serial Port Configuration

    PLC, and the serial port selected by the serial port should be consistent with the selection of [Device Link] in the PLC serial port and protocol parameters Shenzhen King Pigeon Hi-Tech Co.,LED Pages 18 Total 58 Ver 1.2...
  • Page 19: Protocol Parameter

    2. To modify the port number, you must select the [Modbus TCP Server] protocol in the server protocol to modify. The port number is mainly used with the [Modbus TCP Server] protocol when Shenzhen King Pigeon Hi-Tech Co.,LED Pages 19 Total 58...
  • Page 20: Server Configuration

    If it times out, the heartbeat packet will be sent according to the "reconnection times". If the number of sending times is reached, it will be Shenzhen King Pigeon Hi-Tech Co.,LED Pages 20 Total 58 Ver 1.2...
  • Page 21: D225 Application Case

    IP/domain name and port number. Whether to fill in other options according to your needs. (2) Choosing the King Pigeon (KPIOT )2.0 protocol and the King Pigeon 3.0 protocol is to connect to the company's cloud platform, server IP/domain name and port number, heartbeat packet and heartbeat response packet.
  • Page 22: Fx3Uand D225 Device Connection

    (3) and (4) connected via RS422 to RS232 cable, the RS422 interface of the PLC is connected to the D225 device RS232 interface, (5) PLC power cord, (6) If the D225 device is not connected to the PLC RS422 interface, it can also be connected to the D225 device through...
  • Page 23: Configuration Software Configuration

    After modifying the configuration, you need to click [Save Parameters]. After the save is successful, click the "Restart" button to restart the device or the D225 device is powered off, power on and restart, and the modified configuration can take effect ote: 1.
  • Page 24: Use Modbus Poll Tool To Simulate The System To Collect Plc Data

    (4) Collect the number corresponding to D225, see of D225 mapping addresses, because D0-D31, there are 32 registers in total, so the number is "32", (5) Other setting items are default, you can also modify the configuration according to the requirements, click "OK"...
  • Page 25: The Data Configuration Of Collecting Fx3U Output Y Is As Follows: Collecting Y0- Y7

    Y0-Y7 is 5000-5007, so the starting address is filled in "5000", (PLC Appendix Mapping The mapping address of the register corresponding to D225 is detailed in the address of PLC register) (5) Y0-Y7, there are 8 in total, so the number is filled in: "8"...
  • Page 26: The Communication Connection Configuration With D225 Is As Folows

    (2) The communication protocol with D225 is: Modbus TCP, (3) Fill in the address of the D225 device, note: the address should be the same as [on the D225 configuration software The [IP address] configuration of the network settings is the same, (4) fill in the port number of the...
  • Page 27: Description Of The Message Format For Collecting Mitsubishi Fx3U Data

    Description of the message format for collecting Mitsubishi FX3U data Take the data of Y0-Y7 as an example, the mapping address of D225 device: 5000-5007, the number of collection: 8 Modbus Poll: Data sent TX: 07 9C 00 00 00 06 01 01 13 88 00 08...
  • Page 28 20 Low acquisition number D225 Device returns data RX:07 9D 00 00 00 43 01 03 40 00 1E 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...
  • Page 29: Data Acquisition Of Siemens Plc

    Note that the data A and B of the PLC RS485 port should correspond to the A and B of the RS485 interface of the D225 2. The network cable of D225 in the example shown in the figure is connected to the router and in the same local area network as the computer.
  • Page 30: D225 Configuration Sw Configuration

    2. After modifying the configuration information, you need to click "Save parameters". After prompting that the save is successful, click the "Restart" button to restart the device or the D225 device is powered off, restarted, and the modified configuration can take effect Operation instructions: (1) After selecting the device to be configured and logging in (in this example, double-click the IP address: 192.168.1.250 to log in), select the same PLC protocol...
  • Page 31: Data Configuration Of Acquisition Variable Register Vw

    PLC register), (4) Siemens S7-200 SMART output point Q0.0-Q0.7 data, corresponding to D225 mapping address: 5000-5007, so fill in the starting address as: 5000, (For details about the mapping address of PLC register corresponding to D225, please Appendix Mapping address of PLC register...
  • Page 32 Appendix Mapping address of PLC register) (6) corresponding to D225, please refer to the VW0-VW9, there are 10 in total, so fill in the number "10" (7) Other configuration defaults, click "OK", so that the collected VW data is configured, (8) click "Save" to modify the file name Shenzhen King Pigeon Hi-Tech Co.,LED...
  • Page 33: Communication Connection Configuration With D225

    Communication connection configuration with D225 Operation instructions: (1) Click "Connect…" of "Connection" to pop up the connection configuration box, (2) The communication protocol with D225 is: Modbus TCP, (3) fill in the address of the D225 device, note: the address should be the same as the [on the D225 configuration...
  • Page 34 PLC Data acquisition protocol conversion gateway -D225 Programming software query data as follows The data collected by Modbus Poll is exactly the same as the data seen on the programming software Shenzhen King Pigeon Hi-Tech Co.,LED Pages 34 Total 58 Ver 1.2...
  • Page 35: The Description Of Data Message Format For Collecting Siemens S7-200 Smart

    The description of data message format for collecting Siemens S7-200 SMART Take the data of Q0.0-Q0.7 as an example, the mapping address of the D225 device: 5000-5007, the number of collections: 8 Modbus Poll: Data sent TX: 00 F4 00 00 00 06 01 01 13 88 00 08...
  • Page 36: Three-Phase Multi-Function Meter Data Collection

    0A Low order of acquisition quantity D225 device returns data RX: 00 F5 00 00 00 17 01 03 14 00 1B 1B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...
  • Page 37: Use Modbus Poll Tool To Simulate The System To Collect Data From Three-Phase Multi-Function Meters

    DL/T645-1997 or DL/T645-2007 protocol, select The device protocol is DL/T645 protocol, (2) Because the D225 device and the meter are connected through RS485, so choose the serial port 2 (485), (3) This example takes Modbus TCP Server protocol as an example, so choose Modbus TCP Server The default number is "502"...
  • Page 38 "000000000000", the protocol of the electric meter is DL/T645- 2007, Therefore, the corresponding D225 mapping address for phase A, B, and C voltage of the meter is: 50-52, so the starting address is filled in: 50, (for the mapping address of the meter...
  • Page 39 (2) The communication protocol with D225 is: Modbus TCP, (3) Fill in the address of the D225 device, note: the address should be the same as D225 The [IP address] configuration of [Network Settings] on the configuration software is the same. (4) Fill in the port number of the D225 device.
  • Page 40: Connect To The Cloud Platform Application Instructions

    Connect to the cloud platform application instructions Take the connection to the King Pigeon (KPIOT) 3.0 platform as an example, the PLC selection is Mitsubishi FX3U, which is connected through the RS232 interface of the D225 device 5.4.1 D225 Configuration SW of configuration...
  • Page 41: King Pigeon (Kpiot 3.0) Platform Configuration

    (3) choose Jingeyun 3.0 for server protocol The system defaults and does not need to be modified. (4) For the registration code, please contact the sales representative of King Pigeon. The heartbeat packet and heartbeat response can be left blank or filled. According to your own needs, the company's Jin Ge 3.0 platform is fixed The heartbeat packet and the heartbeat response packet...
  • Page 42 Operation steps description: (1) Fill in the registration code (the registration code obtained from the sales representative of King Pigeon), (2) After filling in the registration code, the server communication protocol and product name will be automatically displayed here, (3) The device name is filled in according to your needs, The icon can also be modified, click "modify"...
  • Page 43: Monitor D225 Equipment To Collect Plc Data Points

    Operation instructions: (1) Add new collected data points, which can be added single or multiple, (2) Name the collected data points, (3) The slave address is the ID of the D225 device, the defaults to "1" , (4) Select the register type according to the value type of the data point to be collected.
  • Page 44: Modify The Collection Point

    PLC Data acquisition protocol conversion gateway -D225 Explanation: (1) You can see whether the device D225 is online, (2) You can choose the arrangement of the collected data points, (3) Collect the data of FX3U output Y0, from the figure...
  • Page 45 The procedure for adding a new data point is the same as the method of establishing a data point when creating a new device. After adding or modifying the previous data point, click "OK". Shenzhen King Pigeon Hi-Tech Co.,LED Pages 45 Total 58 Ver 1.2...
  • Page 46: Remote Debugging Of Mitsubishi Plc Program

     Find the domain name corresponding to the external network IP on the router Because the IP address of the external network is a dynamic address and changes, in order to facilitate the D225 device to maintain communication with the server using a dynamic domain Shenzhen King Pigeon Hi-Tech Co.,LED Pages 46 Total 58 Ver 1.2...
  • Page 47 Kemai dynamic domain name or a 3322 dynamic domain name, which can be registered according to the needs of customers.  D225 Configuration SW as below Note: To modify the configuration, you need to log in to the configuration software, select the...
  • Page 48 (7) After configuration, you need to click save parameters, and click the "restart" button to restart the device or D225 device after the save is successful Power off, power on and restart, the modified configuration will take effect ...
  • Page 49: Restore Factory Setting

    PLC Data acquisition protocol conversion gateway -D225 6 Restore factory setting When D225 needs to be restored to the factory, there are two methods: 1. Through the configuration SW settings Click "Restore Factory" → "Save Parameters" → click "Restart" button or "Restart device after power off".
  • Page 50: Appendix Mapping Address Of Plc Register

    Modbus address mapped by Mitsubishi Fx-2N register: PLC Register type Type of data Type Device Mapping Support data address function code Input contact X X0~X377 On-off 0~255 type Shenzhen King Pigeon Hi-Tech Co.,LED Pages 50 Total 58 Ver 1.2...
  • Page 51 Timer contact TS T0~T63 On-off 10000~10063 01、05 type Counter contact CS C0~C31 On-off 12000~12031 01、05 type State relay S S0~S127 On-off 14000~14127 01、05 type Auxiliary relay M M0~M511 On-off 34000~34511 01、05 Shenzhen King Pigeon Hi-Tech Co.,LED Pages 51 Total 58 Ver 1.2...
  • Page 52 Special relay SM M8000~M8511 On-off 54000~54511 type Timing register T T0~T137 numeric 0-137 03、06 type Counter register C C0~C31 numeric 2000-2031 03、06 type C200-C255 numeric 52000-52111 03、06 Counter register(32 bit) type Shenzhen King Pigeon Hi-Tech Co.,LED Pages 52 Total 58 Ver 1.2...
  • Page 53 VD0~VD8188 numeric 44000-60377 03、06 type Note: In order to be compatible with all PLC types of Siemens, various registers can collect at most 32 mapping addresses at a time. Shenzhen King Pigeon Hi-Tech Co.,LED Pages 53 Total 58 Ver 1.2...
  • Page 54: Appendix Mapping Address Corresponding To Three-Phase Multi-Function Meter

    Phase B voltage true value 000000000000 10042 16bit int Phase C voltage true value 000000000000 10043 16bit int Y=X/100 Phase A current 000000000000 10044 16bit int Y=X/100 Phase B current Shenzhen King Pigeon Hi-Tech Co.,LED Pages 54 Total 58 Ver 1.2...
  • Page 55 Total positive power …. …. …. …. …. …. 000000000002 10200 Total positive power 32bit int Y=X/100 …. …. …. …. …. …. 000000000099 19900 Total positive power 32bit int Y=X/100 Shenzhen King Pigeon Hi-Tech Co.,LED Pages 55 Total 58 Ver 1.2...
  • Page 56 Positive reactive valley electricity 000000000000 kVarh 32bit int Y=X/100 Reverse total reactive power 000000000000 32bit int kVarh Y=X/100 Reverse reactive power point 000000000000 kVarh 32bit int Y=X/100 Reverse peak reactive power Shenzhen King Pigeon Hi-Tech Co.,LED Pages 56 Total 58 Ver 1.2...
  • Page 57 16bit int — Y=X/1000 A phase power factor 000000000000 — 16bit int Y=X/1000 B-phase power factor 000000000000 16bit int — Y=X/1000 C-phase power factor 000000000000 16bit int Y=X/100 Grid frequency Shenzhen King Pigeon Hi-Tech Co.,LED Pages 57 Total 58 Ver 1.2...
  • Page 58: Pages 3 Total

    …. …. …. …. 000000000002 32bit int Y=X/100 Combination 1 total active power …. …. …. …. …. …. 000000000099 9900 32bit int Y=X/100 Combination 1 total active power Shenzhen King Pigeon Hi-Tech Co.,LED Pages 58 Total 58 Ver 1.2...