Commissioning, inspection, maintenance
Adjusting the burner
Calculating factor f
0.765
0.755
0.745
0.735
0.725
0.715
0.705
0.695
0.685
0.675
5
6
7
8
Operating pressure in bar
Fig. 17
M75C
A
With ECO 2
With ECO 1
B
Without ECO
C
Calculating the combustion heating output
Combustion heating output in kW = factor f x nominal steam mass flow rate in kg/h
Example:
Nominal steam
10,000 kg/h M75C
mass flow rate
Operating pressure
42
(cont.)
9
10
11
12
13
14
1. Operation with ECO 2
Factor f = 0.689 results in combustion heating output = 6890 kW, curve
11 bar
at 11 bar
2. Operation with ECO 1
Factor f = 0.702 results in combustion heating output = 7020 kW, curve
at 11 bar
3. Operation without ECO
Factor f = 0.745 results in combustion heating output = 7450 kW, curve
at 11 bar
15
16
17
18
19
20
C
B
A
21
22
23
24
A
B
C