STALLATION DIAGRAMS
MILO 1L PANELS
This diagram shows how to use the Ref 1490 module as a SAFETY RELAY (AP1) and as
a SECOND LOCK RELEASE ACTIVATION (AP2).
• AP1': Main lock release (activated from the outdoor panel).
• AP1: Main lock release (activated from the module REF. 1490).
• AP2: Second lock release (activated from the module REF. 1490).
• P1: Direct activation of the AP1 lock release.
• P2: Direct activation of the AP2 lock release.
• P3: Simultaneous direct activation of the AP1 and AP2 lock releases.
NOTES:
• This diagram corresponds to outdoor panel version V2.02 and onwards.
• The outputs for AP1 and AP1' (main lock releases) act simultaneously.
• To use the SAFETY RELAY, connect the main lock release as AP1.
• To use the SECOND LOCK RELEASE ACTIVATIONS, connect the main lock release as
AP1' (or as AP1 if the SAFETY RELAY function is also required) and the secondary lock
release as AP2.
• Run the AP1 connection cables through a protective conduit, separate from the outdoor
panel cables.
6
DOOR RELAY MODULE REF. 1490