Hmf - Technical Data - gefran HMF Series Instruction Manual

Smart hart melt pressure transmitters
Table of Contents

Advertisement

Accuracy (1)
Resolution
Measurement range
Rangeability
Maximum overpressure (without degrading performances)
Measurement principle
Power supply
Maximum current absorption
Output signal Full Scale (FS)
Zero balance (tollerance ± 0.25% FS)
Calibration signal
Power supply polarity reverse protection
Compensed temperature range housing
Operating temperature range housing
Storage temperature range housing
Thermal drift in compesated range: Zero / Calibration / Sensibility
Diaphragm maximum temperature
Zero drift due to change in process temperature (zero)
Standard material in contact with process medium
Protection degree
Electomagnetic compatibility – Emissions
Electomagnetic compatibility – Immunity
FS = Full scale output
(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.
Sense resistor Load Line
900
800
700
600
500
400
300
200
100
0
10
12
14
16
250 ohm minimum for HART communication
Sensors are manufactured in compliance with:
- EMC compatibility directive
- FM Approval Scheme (except version 2)
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
80636B_MAN_HMF - HWF_05-2022_ENG
4�2� HMF – Technical data
WORKING AREA
18
20
22
24
26
Vcc (V)
H <±0.25%FS (100...2000 bar)
M <±0.5%FS (17...2000 bar)
16 bit
0..17 to 0..1000bar
0..250 to 0..15000psi
3:1
2 x FS
1.5 x FS above 1000bar/15000psi
Extensimetric
13...30Vdc
23mA
20mA
4mA
80% FS
Yes
0...+85°C
-30...+85°C
-40...+125°C
< 0.02% FS/°C
400°C / 750°F
< 0.02 bar/°C
Diaphragm:
• 15-5 PH with GTP+ coating
• 17-7 PH corrugated diaphragm with GTP+ coating for ranges
<100 bar (1500psi)
Stem:
• 17-4 PH
IP67 / NEMA 4X
EN 61326-1
EN 61326-2-3
EN 61326-3-1
EN 61326-1
EN 61326-2-3
EN 61326-3-1
28
30
32
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hwf seriesHwf pHwf sHmf pHmf s

Table of Contents