Procedure for setting a time program
The following explains how to input the settings for a
time program. The specifics of the individual time pro-
grams can be found in the relevant chapters.
The time programs can be set individually to be the
same, or different, for every day of the week.
You can set up a time program for the following functions:
Function
Within the time phase
Central heating
Weather-compensated operation:
Your rooms are heated with standard room
temperature or comfort room temperature.
Constant operation:
Your rooms are heated with standard flow
temperature or comfort flow temperature.
Room temperature-dependent operation:
A time program for central heating can only be set at the room temperature controller.
DHW heating
DHW heating is switched on.
The water in the DHW cylinder is heated to
the set DHW temperature.
DHW circulation
The DHW circulation pump is switched on.
pump

Time programs and time phases for central heating

Note
In room temperature-dependent operation, a time pro-
gram for central heating can only be set at the room
temperature controller: See the operating instructions
for the room temperature controller.

Setting time phases

You can set up to 4 time phases in each time program.
For each time phase, you define a start and end point.
Example:
Time program for "Monday" for "Heating circuit 1"
Time phase 1:
06:30 to 12:00 with standard room temperature
Time phase 2:
15:00 to 21:00 with comfort room temperature
In between these time phases the system heats to a
reduced temperature.
Tap the following buttons:
01. Call up the home screen.
02.
press and hold for approx. 3 s.
03.
for "Time programs"
Operating instructions for room temperature controller
In the time programs you determine what your heating
system should do at what time. To do so, divide the
day into sections. These are called time phases. Dif-
ferent temperature levels are active within and outside
these time phases.
Temperature level
Outside the time phase
Your rooms are heated with reduced room
temperature.
Your rooms are heated with reduced flow
temperature.
DHW heating is switched off.
The DHW circulation pump is switched off.
Factory settings: One time phase from 06:00 to 22:00
for every day of the week
04. OK to confirm
05.
for "Heating"
06. OK to confirm
07.
for "Heating circuit 1" (required heating
circuit, if several heating circuits are installed)
08. OK to confirm
09.
for "Monday" (required day of the week)
10. OK to confirm
11.
for the time phase "06:00 - 22:00"
(required time phase that needs to be changed)
12. OK to confirm
Time programs
21