YTL D119014 User Manual

Single-phase two-wire meter

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D119014 and is the answer not in the manual?

Questions and answers

Summary of Contents for YTL D119014

  • Page 2: Features And Technical Parameters

    1. Introduction This is a single phase meter with communication RS485 and RF. Protocol for RS485 is DTL645. Meter with inside relay support for connect and disconnect functions. 2. Features and Technical Parameters 2.1 Features ●LCD display show voltage, current, power, and kWh. ●Measuring total energy consumption, support both active and reactive energy measurement.
  • Page 3 3. Description relay status Impulse indication Turn Page Button Material Case: ABS+PC Hook: ABS material...
  • Page 4: Connection Diagram

    4. Display 4.1 LCD content 4.2 Parameters show on the LCD screen LCD display for present total kWh, press button can be used to turn to different pages, totally 4 pages ● Page 1: active power 000000.00 kWh ● page 2: voltage 000.0 V ●...
  • Page 5: Meter Dimensions

    6. Meter Dimensions Height 100mm Width 76mm Depth 65mm Weight 0.3174kg(Net) 7. Software Connect the meter correctly with power according to connection diagram, includes RS485 wire; then power on...
  • Page 6 7.1 RS485 communication: 7.1.1 Open the software (see following interface): 7.1.2 Choose the serial port, baud rate and open the serial port (see following interface)
  • Page 7 7.1.3 Input the correct meter address ( 000000000000), and choose the object Factory Default which need to be operated, then click send data,as following: 7.1.4 When use broadcast address operate meter needs press button on the meter 7.1.5 This meter without load curve and RTC...
  • Page 8: Installation Instruction

    9. Installation Instruction Choose 35mm standard Din-Rail ( the length is confirmed by yourself ), fixed them in the location which are waiting for installation; Push down the clip under the bottom of the meter for a gear, see fig. 1; Fig.1 Put the meter into the Din-rail as per Fig.
  • Page 9 Fig. 4 is after installation; Fig.4 Making the connection according to the wiring diagram, see Fig. 5 Fig.5...
  • Page 10 After connection, use lead sealing to seal terminal cover, see Fig. 6 Fig.6...
  • Page 11 Recommended wire(For your reference) : Safe carrying capacity of rubber or plastic insulated wire(1) Safe carrying capacity(A) nominal cross section specification(mm) (mm2) 1*1.13 1*1.37 1*1.76 1*2.24 1*2.73 7*1.33 7*1.76 7*2.12 7*2.50 19*1.83 19*2.14 19*2.50 Note: BX(BLX) copper (aluminum) core rubber insulated wire or BV(BLV) copper (aluminum) core PVC plastic insulated wire,widely used in 500V or less than 500V AC and DC power distribution system.
  • Page 12: Safety Instructions

    The equipment (device, module) may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by YTL. Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible.
  • Page 13: General Warning

    The manufactory will repair or exchange the products while the lead seal is still exited, within 18 months, when discovering the products not accordance with the technical specification. Technical support For any problems of our products please contact: Zhejiang Yongtailong Electronic co.,ltd No. 320 Tongsheng road, Tongxiang Zhejiang, China Post:314500 Web: www.ytl-e.com Tel: 0573-88105687 Fax: 0573-88100423...