PERFORMANCE DATA - 4 TON

CONDENSER-ONLY DATA (OUTDOOR UNIT)
SATURATED SUCTION
@ COMPRESSOR
MODEL
T (°F)
35
40
45
TH6B4821S
50
55
60
Notes:
1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.
2. Performance based on 15ºF subcooling and 15ºF superheat at the Outdoor Unit base valves.
a. Increase capacity by 1% for each 2ºF increase in subcooling.
b. Decrease capacity by 1% for each 2ºF decrease in subcooling.
3. Maximum recommended condensing temperature is 140ºF.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
IDCFM
AIR TEMP.
ENTERING
ID DB (°F)
OUTDOOR UNIT (°F)
ID WB (°F)
65
75
85
95
105
115
125
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Green shaded cells are ACCA (TVA) conditions.
Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
76
65 °F
P (PSIG)
MBH
KW
107
41.1
1.97
119
46.4
1.99
130
51.8
2.00
143
57.2
2.02
156
62.5
2.04
170
67.9
2.05
TH6B4821S
1350
80
80
75
57
62
62
T.C.
42.9
47.3
47.4
S.C.
42.9
39.1
33.0
KW
2.80
2.83
2.82
T.C.
41.4
45.3
45.6
S.C.
41.4
38.0
32.2
KW
3.08
3.09
3.10
T.C.
39.8
43.3
43.8
S.C.
39.8
36.9
31.5
KW
3.35
3.35
3.37
T.C.
38.8
41.5
42.4
S.C.
38.8
36.3
27.6
KW
3.73
3.71
3.73
T.C.
37.7
39.6
40.9
S.C.
37.6
35.7
23.7
KW
4.11
4.08
4.10
T.C.
36.3
37.9
39.3
S.C.
36.2
34.8
24.9
KW
4.51
4.48
4.34
T.C.
34.8
36.3
37.7
S.C.
34.8
33.9
26.1
KW
4.91
4.88
4.59
Outdoor Ambient Temperature
75 °F
85 °F
MBH
KW
MBH
KW
MBH
39.4
2.31
37.7
2.64
36.0
44.3
2.32
42.1
2.65
40.0
49.2
2.33
46.6
2.66
44.0
54.1
2.35
51.1
2.67
48.1
59.0
2.36
55.6
2.68
52.1
64.0
2.37
60.0
2.69
56.1
1600
80
80
80
80
75
67
72
57
62
62
51.6
55.5
44.9
48.8
48.8
32.1
24.4
44.9
42.0
35.3
2.84
2.85
2.92
2.94
2.94
51.0
55.4
43.3
46.7
47.0
32.7
25.6
43.3
41.1
34.7
2.82
2.84
3.20
3.20
3.21
50.3
55.3
41.8
44.6
45.1
33.3
26.8
41.8
40.2
34.2
2.80
2.83
3.47
3.47
3.48
48.1
53.1
40.6
42.6
43.6
32.5
26.0
40.6
39.6
29.7
3.16
3.19
3.84
3.83
3.85
45.9
50.9
39.3
40.6
42.1
31.6
25.2
39.3
39.0
25.2
3.51
3.55
4.22
4.19
4.21
43.9
48.7
37.7
39.0
40.4
30.8
24.4
37.7
37.6
26.7
3.91
3.95
4.62
4.59
4.43
41.8
46.6
36.2
37.4
38.8
29.9
23.7
36.2
36.3
28.2
4.30
4.35
5.02
4.99
4.65
95 °F
105 °F
115 °F
KW
MBH
KW
MBH
2.98
34.3
3.32
32.6
2.99
37.8
3.32
35.7
2.99
41.4
3.32
38.8
3.00
45.0
3.33
42.0
3.00
48.6
3.33
45.1
3.01
52.2
3.33
48.2
80
80
80
80
67
72
57
62
52.8
55.9
46.8
50.4
33.6
25.1
46.8
44.9
2.96
2.96
3.04
3.05
52.4
56.5
45.3
48.2
34.9
26.8
45.3
44.2
2.88
2.90
3.31
3.32
51.9
57.1
43.8
45.9
36.1
28.4
43.8
43.5
2.80
2.83
3.59
3.58
49.7
54.9
42.4
43.7
35.3
27.7
42.4
42.9
3.16
3.19
3.96
3.94
47.4
52.6
41.0
41.5
34.4
26.9
41.0
41.5
3.52
3.55
4.33
4.30
45.3
50.3
39.2
40.0
33.6
26.2
39.2
40.0
3.91
3.95
4.73
4.70
43.2
48.1
37.5
38.5
32.8
25.5
37.5
38.5
4.31
4.35
5.13
5.11
Johnson Controls Ducted Systems
125 °F
KW
MBH
KW
3.66
30.9
3.99
3.66
33.6
3.99
3.65
36.2
3.98
3.65
38.9
3.98
3.65
41.6
3.97
3.65
44.3
3.97
1850
75
80
80
62
67
72
50.1
54.0
56.3
37.6
35.1
25.9
3.05
3.07
3.08
48.3
53.8
57.6
37.2
37.0
28.0
3.32
2.94
2.96
46.4
53.6
58.9
36.9
38.9
30.1
3.60
2.81
2.84
44.8
51.2
56.6
31.8
38.1
29.4
3.96
3.17
3.20
43.2
48.9
54.3
26.7
37.3
28.7
4.32
3.52
3.56
41.6
46.7
52.0
28.5
36.5
28.0
4.52
3.92
3.96
39.9
44.6
49.6
30.2
35.6
27.3
4.72
4.31
4.36

Advertisement

Table of Contents
loading

Table of Contents