Storage; Electromagnetic Compatibility; Power Supply - Lanex TM-77 Operating Manual

Table of Contents

Advertisement

7.4.3 Storage

The devices should be stored in closed rooms in the following environmental conditions:
Environmental
Parameter
Ambient temperature
Humidity
Vibrations
Degree of contamination
7.5

Electromagnetic compatibility

The devices comply with the requirements for class B equipment concerning radioelectric
disturbance emissions, set out in PN-EN 55022 standard, provided that they are installed
in accordance with this Manual.
7.6

Power supply

Parameter
or feature
Rated power supply voltage for
device with typical power supply unit
Rated power supply voltage
Input current at 230 V/AC voltage
Input current at 36 V/DC voltage
Input current at 60 V/DC voltage
Input current at 18 V/DC voltage
Input current at 60 V/DC voltage
Types of connectors
IOA77-1F
4
E1/G.703 P
X
LESIOCHRONOUS
O
PERATING
frequency: 10 Hz up to 55 Hz, amplitude: 0.15 mm
duration: 10 cycles in three planes
TM-77.1
TM-77.1
TM-77.1
TM-77.1
TM-77.1
MD-77.1
MD-77.1
TM-77.1
47
M
ULTIPLEXER
M
ANUAL
Allowable
value
-25 ÷ +55
5% up to 90% below +40
typical home or office environment
Version
Symbol
double (screw) clamp connector
to connect 36-60V DC power
supply source
IEC320 / EN 60320 standard
device connector to connect 230V
AC power supply source
O
C
O
C
Parameter value
or feature description
50 ÷ 60 Hz; 230 V
0 Hz; 18 ÷ 60 V
40 mA
145 mA
90 mA
220 mA
65 mA
May 2007