....................14 PERATING CONDITIONS ........................14 NSTALLATION .......................15 OWER SUPPLY E1/G.703 .................16 LINEAR SIGNAL CONNECTION 4.4.1 TM-77 and MD-77 ....................16 VT100 ONNECTION TO TERMINAL OR COMPUTER WITH INSTALLED ANWIN ......................17 MANAGEMENT SOFTWARE ..................18 IBER OPTIC LINE CONNECTION OPERATION WITH VT100 TERMINAL...............20 ........................20 PPLICATION ...................20...
Page 3
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.1.1 Device name ......................34 6.1.2 Setting date and time .....................34 6.1.3 Additional information ..................35 .......................36 HANNEL ACTIVITY G.826 ......................36 STATISTICS 6.3.1 Alarm severity level....................38 6.3.2 Alarm thresholds ....................39 ........................40 EST LOOPS ........................41 ONITORING ..........................42 6.6.1 Event log........................42 6.6.2...
Page 4
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL List of figures TM-77.1 ........2 IGURE MULTIPLEXERS USED IN TELEPHONE NETWORKS MD-77 IGURE MULTIPLEXERS USED TO CONNECT TELEPHONE SWITCHES AND COMPUTER ...................2 NETWORKS USING NETWORK TM-77 ............5 IGURE IEW AND DESCRIPTION OF FRONT PANEL ............6...
Page 5
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL List of abbreviations AACK Alarm Acknowledgement Alarm Acknowledged Alarm Inhibition Signal AISL AIS from Local interface AISR AIS from Remote device Background Block Error Errored Second ES15 15 Minutes Errored Second Counter ES24 24 Hours Errored Second Counter ESFE Errored Second Far End ETSI...
Page 6
PERATING ANUAL Operating safety TM-77.1 and MD-77.1 devices have been designed and tested for the operating safety in accordance with Class I of PN-EN 60950 standard. The device has no built-in disconnecting system. Such a system should be installed outside the device.
- provided it complies with the requirements of the G.703 recommendation. All TM-77, MD-77, TM-76, MD-76 and TM-44 devices can operate with each other if connected via a fiber optic line. If TM/MD-77 4-channel device is connected to MD-76 or TM- 76 single-channel device, transmission with the first E1 channel is possible.
• as a desktop version in a metal casing, symbol TM-77. • as a card installed in TM-72 telecommunication rack to cooperate with another TM-72 or MD-77 card. Symbol example: TM-77.1-3 – a desktop multiplexer equipped with a laser transmitter of 1310 nm wave length. IOA77-1F May 2007...
Page 10
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Note: 1. Each time a symbol containing the letter "X" instead of its corresponding digit is used in the Manual, it means that the feature specified in this part of the symbol is insignificant concerning the discussed parameter and may be equal to any value from the above-mentioned range.
ACK – acknowledgement of non-urgent alarm AACK – alarm acknowledgment button Figure 3. View and description of TM-77 front panel The device is equipped with V.28 interface enabling multiplexer management from VT100 terminal level. The interface is described in Table 2.
LESIOCHRONOUS ULTIPLEXER PERATING ANUAL RS-232 cable should be used to connect TM-77 multiplexer to the terminal. Table 3 specifies the required list of cable connections. Table 3. PC computer (terminal) to TM-77 connecting cable specification PC computer or terminal side TM-77.1 multiplexer side...
MD-77 multiplexer (card) MD-77.1 AACK MD-77.1 Figure 5. View of TM-77.1 front and rear panels 1 - power supply indication diode 2 - group of signaling diodes: LOESn – loss of electrical signal coming in n-channel LOOS – loss of optical receiver input signal LDF–...
Diagnostic and signaling systems TM-77 and MD-77 type devices automatically control the parameters of E1/G.703 local interface and linear optical signal, and detect and signalize the following conditions and values: G.703 E1 local interface •...
– LED diode is on – alarm relay, an activated alarm is indicated by closed relay contacts (C – closed contacts, O – open contacts). TM-77.1 version is not equipped with alarm relays. Additional channels A frame is generated in the multiplexing system. The frame includes two bits, which are used to generate two additional synchronous bidirectional data transmission channels at the speed of 10 kbit/s each.
ANUAL Test loops TM-77.1 and MD-77.1 device software enables closing a loop on E1 electric interface and optical interface in the direction to and from the device. Concerning E1 interface, both loops are closed at the same time. The figure below shows possible loops. A loop number is consistent with the number used in the device software.
PERATING ANUAL Event log TM-77 and MD-77 devices can record the time and date of an event of a specified criterion. The devices record the following types of events: • an appearance or loss of power supply voltage, • an appearance or loss of G.703 E1 interface input signal, •...
PERATING ANUAL Monitored qualitative parameters of G.703 E1 interface TM-77 and MD-77 devices are provided with a function of qualitative parameter monitoring. The devices automatically monitor the interface signal parameters and detect, count and signalize the following conditions and parameters: Indicators: •...
ANUAL Monitored qualitative parameters of E2 optical interface TM-77 and MD-77 devices are provided with a function of qualitative parameter monitoring. The devices automatically monitor the linear interface signal parameters and detect, count and signalize the following conditions and parameters: Indicators: •...
Installation TM-77 is a desktop device; MD-77 is installed in MD-72 telecommunication rack. MD-77 device comprises a digital card and an interface card. The digital card is installed in the front part of the rack in slots 1÷16 and the interface card is installed in their corresponding slots in the rear part of the rack.
Power supply TM-77 multiplexer can be supplied with 36÷60V DC voltage or 230V AC voltage. MD-77 card is supplied with 18÷60V DC voltage from TM-72 telecommunication rack. Power supply connection is described in TM-72 rack operating manual. Power supply voltage parameters are given in paragraph 7.6.
ANUAL E1/G.703 linear signal connection 4.4.1 TM-77 and MD-77 E1/G.703 interface input and output signals of TM-77 and MD-77 devices are transmitted via two screened symmetric cables of 120 Ω impedance or one double screened cable of the same impedance.
Description of RS-232 / V.28 DCE connector outputs (RJ-45 type) Description SGND RS-232 cable should be used to connect TM-77 multiplexer to the terminal. Table 7 specifies the required list of cable connections. Table 7. TM-77 - computer connecting cable specification PC computer or terminal side TM-77.1 multiplexer side...
0 dB The device can operate with multimode optical fibers. TM-77 and MD-77 multiplexers can operate with a two-fiber optical line based - depending on version - on the optical fibers: • 50/125 or 62.5/125 µm multimode optical fibers - with SC connector terminals;...
Page 25
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Optical fiber connectors - particularly single-mode ones - are very precise components. That is why they should be handled with care, with no excessive forces when connecting and disconnecting them. Also the socket and the plug "ferrule" should be kept ideally clean. If dirty, the socket can be blown with clean compressed air, while the ferrule can be cleaned with isopropyl or ethyl alcohol (denatured alcohol must not be used).
Application The supervision software is adapted to support VT100 terminal; it is used to set up and monitor the functions of TM-77 multiplexer. MD-77 device is installed in the rack and it does not have a contact enabling terminal connection.
ENTER button. The command may be entered in small or capital letters. When the command is identified, TM-77 opens the first window specifying the device type and its address. Then the password entry window opens. It allows the user to enter the password protecting from unauthorized access to the device.
To do this, the user - instead of the password - should enter %code01. Then, the program will generate an 8-digit string, which should be submitted to the LANEX service. Based on the string, an emergency password will be generated enabling 12-hour access to the device.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Main menu The main menu is the entry window to all remaining panels and submenus. Submenus are selected with the ARROWS and ENTER keys. From its level, you can access the following panels: • System •...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Each of the available panels comprises three fields (common to all panels). These are: • panel name and date bar, • device name and address bar, • key shortcut bar. Figure 12. A terminal window example 1.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Figure 13. The System panel The parameters set up in the System panel are listed in Table 12. Table 12. Device set-up registers. The values in the gray fields in the table are given in the phase of production.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Figure 14. Interfaces-selection 5.5.2.1 Interfaces-options The Interfaces-options panel is used to select the following panels: • interface set-up, • viewing 15-minut and 24-hour ES, SES, BBE, UAS, ESFE, SESFE registers, • viewing the objects related to quality monitoring in the set periods Figure 15.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 5.5.2.2 Set-up The Set-up panel is used to: • set up alarm severity levels when exceeding the quality thresholds in 15-minute and 24-hour periods, set up alarm switch-on and switch-off thresholds when exceeding the quality thresholds in 15-minute and 24-hour periods, •...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL an alarm generated by exceeding an appropriate switch-on threshold (which is set up in the Set-up panel). The device stores 16 records of 15-minute counters for each interface and 2 records of 24-hour counters for each interface. Data is recorded only for non-zero counter values.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 5.5.4 Event log This panel displays events concerning the device. The types of recorded events are described in paragraph 3.6. This panel allows the user to delete all events recorded in the device memory using the CTRL+R key combination.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 5.5.5 Monitoring This panel displays parameters, which represent the current status of E1 and E2 interfaces: • interface defect and anomaly monitoring points, • transmission quality monitoring objects related to individual interfaces. The meaning of individual indicators is described in paragraph 3.6.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 5.5.6 Loops TM-77 multiplexer terminal is capable of activating test loops from the side of E1 and E2 interfaces. The test loops are described in paragraph 3.3 Test loops. Figure 21. Loops IOA77-1F May 2007...
UP USING IN PROGRAM The Lanwin application in a local version enables the user to supervise and monitor TM-77 in a desktop version and TM-72 racks equipped with MD-77 multiplexer cards. The description of computer connection is given in paragraph 4.5 Connection to VT100 terminal or computer equipped with LanWin management software.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.1.1 Device name By pressing the "Device name" button you will opens a window, in which you can enter its name. During the operation, the entered name will appear in the active device window and in the window of the device, whose name was modified.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.1.3 Additional information If you press the "Additional information" button, a window will open showing additional information concerning the connected device. Figure 25. Additional information IOA77-1F May 2007...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Channel activity The "Channel activity" tab allows the user to switch on and off a single E1 transmission channel. If you switch off a channel, it will block transmission in the channel and deactivate all alarm criteria associated with the channel.
Page 43
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Figure 27. G.826 statistics IOA77-1F May 2007...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.3.1 Alarm severity level The window shown below allows you to set an alarm severity level. The window will open if you select the "Alarm severity level" option from the Menu. Figure 28. G.826 statistics, Alarm severity level IOA77-1F May 2007...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.3.2 Alarm thresholds The window shown below allows you to set an alarm switch-on and switch-off threshold. The window will open if you select the "Threshold set-up" option from the Menu. Figure 29. G.826 statistics, Alarm thresholds IOA77-1F May 2007...
ULTIPLEXER PERATING ANUAL Test loops The tab "TM-77 test loops" allows you to activate the test loops from the side of E1 and E2 interfaces. The test loops are described in paragraph 3.3 Test loops. Figure 30. Test loops IOA77-1F...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Monitoring This panel displays parameters, which represent the current status of E1 and E2 interfaces: • interface defect and anomaly monitoring points, • transmission quality monitoring objects related to individual interfaces. The meaning of individual indicators is described in paragraph 3.7. Figure 31.
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL 6.6.1 Event log The "Event log" tab displays the recorded events concerning the multiplexer. The types of recorded events are described in paragraph 3.5. This tab allows you to delete the complete list of recorded events. You can do this by clicking the right mouse button (when the cursor is placed in this window) and selecting the "Delete the log"...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL It allows you to select an event filtering time criterion. This tab enables you to select the start and end date and time of this criterion. • UAL/NUAL It allows you to select criteria of the displayed events analogous to the ones specified for: •...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL ECHNICAL SPECIFICATION Electrical characteristics of E1/G.703 interface Parameter Parameter value or feature or feature description Electrical compatibility ITU-T G.703 standard 2.048 Mbit/s ±50 ppm Rated binary bit rate 2.048 Mbit/s ±50 ppm AIS signal binary bit rate Input and output impedance 120Ω...
Page 51
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Optical interface characteristics Parameter Version Parameter value or feature Symbol or feature description TM 77.1-X Linear code 5B-6B MD 77.1-X TM 77.1-X Optical signal modulation speed 10.1376 Mbod MD 77.1-X TM 77.1-2-X LED 1310 nm MD 77.1-2-X TM 77.1-3-X Optical transmitter type...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL Mechanical parameters Symbol Feature Value Width 224.5 mm Height 52.5 mm (incl. feet) TM-77.1 Depth Weight 1.3 kg Digital card Interface card Width 20.5 mm 20.5 mm MD-77.1 Height 130.5 mm 130.5 mm Depth...
Symbol or feature description Rated power supply voltage for 50 ÷ 60 Hz; 230 V TM-77.1 device with typical power supply unit 0 Hz; 18 ÷ 60 V Rated power supply voltage TM-77.1 Input current at 230 V/AC voltage TM-77.1...
E1/G.703 P LESIOCHRONOUS ULTIPLEXER PERATING ANUAL OMPLETE PRODUCT The complete set of the TM-77 desktop multiplexer supplied to the customer includes the following components: 1. TM-77 multiplexer 1 pce. 2. RS-232 cable, DSUB-9 RJ-45 1 pce. 3. IOA77-1F Operating Manual 1 pce.