Operation Manual / 4 Product description / A100-L
5 Operation and service / 5.2 Service work
NOTICE
5-year service inspection
To prevent machine damage caused by ageing and downtime, we recom-
mend having an inspection carried out by an ABB Turbocharging Service Sta-
tion no later than 5 years after the last service.
5.2.1
Service work every 25 ... 50 hours
CAUTION
Unknown operational changes
Impairment to the degree of a possible operating failure can be the con-
sequence.
Have any unknown causes clarified by an ABB Turbocharging Service Sta-
u
tion.
Visual check for air, exhaust gas, water and oil leaks.
u
Record operating data and enter in the engine logbook.
u
In case of deviations, determine the cause.
u
5.2.2
Service work at 100 hours after commissioning
Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
u
gine is stopped.