N2115 Sas/Sata Hba For Ibm System X Certifications And Safety Characteristics - IBM N2115 Hardware User's Manual

Table of Contents

Advertisement

N2115 SAS/SATA HBA for IBM System x Hardware User's Guide
March 2013
Relative humidity range: 5 percent to 90 percent noncondensing
Maximum dew point temperature: 32°C (89.6 °F)
Minimum airflow: 200 linear feet per minute
The following limits define the storage and transit environment for the HBA:
Temperature range: −45°C to +105°C (−49°F to +221°F) (dry bulb)
Relative humidity range: 5 percent to 90 percent noncondensing
6
N2115 SAS/SATA HBA for IBM System x Certifications and Safety
Characteristics
The HBA meets or exceeds the requirements of UL flammability rating 94V-0. Each bare board is marked with the
supplier's name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe bus slot,
all voltages are less than the SELV 42.4-V limit.
The design and implementation of the HBA minimizes electromagnetic emissions, susceptibility to radio frequency
energy, and the effects of electrostatic discharge.
The HBA meets the following integrated electromagnetic interference (EMI) compliance labels:
CE mark
CISPR Class B
C-Tick mark
Canadian Compliance Statement
FCC Class B, marked with the FCC Self-Certification logo
Japan VCCI
Korean KCC
Taiwan BSMI
The HBA meets the following environmental directives:
RoHS
WEEE
N2115 SAS/SATA HBA for IBM System x Hardware User's Guide

N2115 SAS/SATA HBA for IBM System x Certifications and Safety Characteristics