Operating manual Table of contents INTRODUCTION ......................... 3 DESCRIPTION AND OPERATION OF THE PRODUCT ..........4 Description ..........................4 Technical specifications ......................4 Structure and operation of the Product .................. 4 Measurement instruments, tools and appliances ..............7 Marking and sealing ......................7 Packaging ..........................
Power supply unit PS-203-40 INTRODUCTION This operating manual (hereinafter – OM) describes composition, structure, op- eration and technical service of power supply units PS-203-40 type (hereinafter – the Product). In addition to the instructions given in this document, the safety regulations and rules applicable in the field shall be observed.
Operating manual DESCRIPTION AND OPERATION OF THE PRODUCT 1.1 D ESCRIPTION The Product operates with single-phase AC, frequency 50 (60) Hz, voltage 110 V or 220 V. It powers different shipborne and industrial equipment with regulated voltage 24 V DC. The PS-203-40 has a function of load switch to standby power. 1.2 T ECHNICAL SPECIFICATIONS Table 1 describes technical specifications of the Product.
Page 5
Power supply unit PS-203-40 Figure 1 – The Product Table 2 describes functional elements and controls of the Product. Table 2 – Functional elements, controls and LED light indicators of the Product Type, size, identifi- № Element Description Piano type switch Piano type switch to switch on/off power, –...
Page 6
Operating manual ing. SB voltage to power external signaling unit AU-106 (AU-206) is connected to “Alarm” terminal. Table 3 describes assignment of connector terminals. Figure 2 – Connection diagram Table 3 – Assignment of PS-203-40 connector terminals Terminal Connector Description №...
Power supply unit PS-203-40 1.4 M EASUREMENT INSTRUMENTS TOOLS AND APPLIANCES Table 4 below describes consumables required for the TS. Table 4 – Consumables required for the TS Amount of Name and identifier of consumables Note consumables 1 To clean the Product surfac- es –...
Operating manual INTENDED USE OF THE PRODUCT PERATIONAL LIMITATIONS Select an installation place in compliance with operational limitations (operating temperature and protection degree). Caution! Distance between the installation site and magnetic compass shall not be less than 1 m! SAGE PREPARATIONS 2.2.1 Safety features While preparing the Product for operation, check it visually and make sure there is no mechanical damage.
Page 9
Power supply unit PS-203-40 f) using voltmeter, measure output voltage on connectors’ contacts (for load connection); measured values shall be 24 V DC. If measured voltage is different from the rated value, the Product is not ready for operation. Contact the Manufacturer; g) transfer piano type switch to “OFF”...
Operating manual TECHNICAL SERVICE OF THE PRODUCT 3.1 G ENERAL DESCRIPTION Before performing the TS the staff shall familiarize with the Product structure and operation features. In order to provide safe and reliable operation for the Product, the staff shall maintain semi-annual TS.
Power supply unit PS-203-40 Table 7 – CL №2. Test of output voltage Man-hours To be done Routine per 1 Prod- 1 Switch on the Product power supply 1 person 2 Connect a voltmeter to output terminals of the Product Test of output voltage 3 Supply power to the Product 15 mins...
Operating manual CURRENT REPAIR OF THE PRODUCT 4.1 G ENERAL DESCRIPTION To provide diagnostics of the problems, see Table 8. If a problem cannot be diagnosed or trouble shooting cannot be provided, con- tact the Manufacturer’s service center. 4.2 S AFETY FEATURES Only qualified personnel, examined in occupational safety may perform repair works.
Power supply unit PS-203-40 STORAGE The Product must be stored in packaging inside areas complying with the re- quired storage conditions (+5°С to +40°С) with the concentration of dust, oil, moisture and aggressive impurities in the air within the required limits for the working areas of production facilities.
Operating manual TRANSPORTATION The Product must be transported in the Manufacturer's transportation package in closed means of transport. Types of shipment: - motor vehicle and railroad transportation in closed means of transport (covered cars, multipurpose containers); - air transportation (in sealed and heated compartments); - sea transportation (in dry service spaces).
Power supply unit PS-203-40 DISPOSAL New equipment, the parts of the Product damaged during operation, and any outage equipment must not be disposed as standard household wastes, since they con- tain the materials suitable for re-use. Decommissioned and non-used components of the Product must be delivered to a special waste disposal center licensed by local authorities.
OM. The Manufacturer will not consider damage claims in case of violation of operating conditions. More information about warranty terms you can find on the official site of “NPK MSA” LLC, section Support. Address and contacts of the Manufacturer's service centre: “NPK MSA”, LLC 26E, Kibalchicha str., 192174, St Petersburg, Russia...
Power supply unit PS-203-40 APPENDIX A (MANDATORY) REGULATORY DOCUMENTS Figure A.1 – Outline and installation dimensions of the Product Page 17 Version 1.0...