Forced operation

Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Cooling Model
Operating mode
Cooling
Indoor FAN Speed
High
Setting Temperature
72°F(22°C)

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
about 3 seconds.
If you want to stop the operation, re-press the button.

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.

Helpful information

Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value
when the fan speed is set to high, and the capacity will be lower
at low or medium fan speed.
High fan speed is recommended when you wish to cool the room
quickly.
Room Temp. 76°F(24°C)
70°F(21°C) Room Temp. < 76°F(24°C)
Cooling
Healthy Dehumidification
High
Healthy Dehumidification Rule
72°F(22°C)
Operating Instructions
Power
button
˚ C
Heat pump Model
74°F(23°C)
Room Temp. < 70°F (21°C)
Heating
High
76°F(24°C)
Owner's Manual 21