Humidity
Humidity can be (de)activated in SETTINGS MENU. If it is set to 'OF', then humidity is no longer
being monitored (not in the appliance and not in the mobile app). Display 'H' does not show any
value and automatically humidity alarm and humidity box refill notification are disabled.
Humidity alarm sounds when 7 days average value of compartment humidity falls below 40% or
rises above 80%, for 7 days constantly.
The alarm key
is removed. Humidity value is blinking rapidly
INFORMATION!
Every time the appliance is switched on, it takes a while until the correct humidity is reached. For
this reason, the alarm is disabled for the first 24 hours after the appliance is switched on to prevent
the unnecessary activation of the alarm. Each time the door is closed, humidity alarm is blocked
for 6 hours.
If the difference between old setpoint and new setpoint is less than 5°C, it has no influence on
humidity alarm.
If setpoint temperature for any compartment is set above or equal to 16°C, humidity alarm is neglected.
Stopping the alarm:
Short press on alarm key will stop the alarm from sounding, alarm key is not illuminated anymore.
Humidity value continues to blink while the humidity is still out of range.
If humidity value reestablishes between 40% and 80% and humidity alarm is active , it will be canceled
automatically.
is illuminated and alarm sound is heard. On press of alarm icon the alarm
.
Operation