8
Commissioning
8.1
Configure the settings on indoor station
E
8.1.1
Enter engineering mode of outdoor station
Note
The mini outdoor station must be on the same network as the indoor station.
Please follow the steps below,
■
Power up the mini outdoor station, the three indicators light up green.
■
After a period of time, the three indicators go out.
■
Press and hold the first pushbutton for 5 s.
■
When the pushbutton module and the three indicators are flashing green at the same time,
the mini outdoor station enters engineering mode.
Product manual 2TMD042200D0021
Commissioning
Unlock indicator
Fi rst pushbutton
P ushbutton m odule
│19