INSTALLATION
Before Installation
Dimensions and Clearances
Too small of a distance from adjacent items may
result in the degradation of freezing capability and
increased electricity costs. Allow over 50 mm of
clearance between the back of the appliance and
the wall when installing the appliance.
A
G
F
B
C
-
Type (mm)
-
a
b
A
700
700
B
1760
1720
C
680
680
D
5
5
E
675
675
F
-
-
G
1309
1309
H
1212
1212
NOTE
• You can determine what type of appliance it is by
looking at the label inside the appliance.
D
E
H
c
d
600
600
1720
1640
710
710
5
5
705
705
-
-
1254
1254
1031
1031
INSTALLATION
Ambient Temperature
• The appliance is designed to operate within a
limited range of ambient temperatures,
depending on the climate zone.
• The internal temperatures could be affected by
the location of the appliance, the ambient
temperature, the frequency of door opening and
so on.
• The climate class can be found on the rating
label.
Climate Class
Ambient Temperature
Range ºC
SN (Extended
+10 - +32
Temperate)
N (Temperate)
+16 - +32
ST (Subtropical)
+16 - +38 / +18 - +38**
T (Tropical)
+10 - +43* / +16 - +43 /
+18 - +43**
* Australia, India, Kenya
** Argentina
NOTE
• The appliances rated from SN to T are intended
to be used at an ambient temperature between
10 ºC and 43 ºC.

Levelling the Appliance

Adjusting the Levelling Leg
If the appliance seems unsteady, or the doors do
not close easily, adjust the appliance's tilt using the
instructions below.