Page 1
User Manual E Series Data Radio ER450 Remote Data Radio EB450 Base Station EH450 Hot Standby Base Station www.trio.com.au Issue 5: February 2004...
Related Products Remote Diagnostics & Other Related Documentation and Products Network Controller Revision History Introduction Part B E Series Overview System Description Definition of E Series Data Radio Operating Instructions E Series Product Range Interpreting Poll Results E Series Features and Benefits...
Page 3
SECTION 1 Part A - Preface Part B - E Series Overview Part C - Applications Part D - System Planning and Design Part E - Getting Started Part F - Operational Features Part G - Commissioning Part H - Maintenance...
Part B E Series Overview Part B E Series Overview Definition of E Series Data Radio E Series Features and Benefits Common Features and Benefits of the E Series Data Radio E Series Product Range half duplex...
Page 7
Part B E Series Overview Features and Benefits of EH450 Hot Standby Base / Repeater Station Features and Benefits of ER450 Remote Data Radio Features and Benefits of EB450 Standard Base / Repeater Station...
0 - 5 2 - D The above example specifies: E Series, Remote Radio, generic 450MHz band, with a specific frequency of 450MHz to 465MHz, a 96/19.2kbps modem, with a bandwidth of 25kHz, diagnostics and standard N type connector. Version: 3/03...
Part B E Series Overview Standard Accessories Part Number Description Part Number Description Duplexers RF Cables and Accessories DUPLX450BR NM/NM/TL NM/NM/TLL DUPLX450BR/5 RFCAB5M RFCAB5M2 DUPLX450BP RFCAB10M RFCAB20M Notes: Frequencies must be specified at time of order. RFCAB20M4 Interconnecting (Feeder Tail) cables must be ordered separately for Externally fitted Duplexers.
Part C Applications Part C Applications Application Detail Generic Connectivity SCADA Systems Telemetry Systems Industries and Applications Information Systems...
Part D System Planning and Design Examples of Predictive Path goodpath.pl3 Major Repeater Site Field Site Modelling 756.69 309.67 Elevation (m) Latitude 031 04 37.49 S 030 56 24.00 S Clear line of site Longitude 150 57 26.34 E 150 38 48.00 E Azimuth 297.05...
Page 15
Part D System Planning and Design Effect of Earth Curvature on Long Paths longpath.pl3 Repeater Site Far Field Site Elevation (m) 221.26 75.58 Latitude 032 01 21.63 S 032 33 00.00 S Longitude 142 15 19.26 E 141 47 00.00 E 217.12 37.37 Azimuth...
Part D System Planning and Design RF Feeders and Protection Data Connectivity The V24 Standard data terminal equipment data communication equipment Note: All ETSI installations require the use of a lightning surge arrestor in order to meet EN6095. See Part A - Preface for lightning arrestor specifications.
Page 18
Part D System Planning and Design Cable Wiring Diagrams...
Page 19
Part D System Planning and Design Cable Wiring Diagrams RS232 Connector Pin outs (DCE) Port A and B, Female DB9...
Part D System Planning and Design Power Supply and Environmental Considerations General Note: Operation below the minimum specified supply voltages could result in poor radio performance. If the supply voltage falls below 7.2Vdc the radio will shut down. Normal radio startup will not occur until 10Vdc is supplied.
Part E Getting Started - ER450 Part E Getting Started ER450 Quick Start Guide Mounting and Environmental Considerations Introduction ER450 Quick Start Guide Note: In high power or high temperature applications, it is desirable to mount the radio with the heatsink uppermost to allow ventilation for the heatsink.
Page 25
Part E Getting Started - ER450 ER450 Connections Layout System Port Description DB9 Female Pin 1 System port data out (RS232) Pin 2 Pin 2 System port data in (RS232) Pin 3 Pin 3 Factory Use Only - Do not connect No Connection Pin 4 Shutdown No Connection...
Page 26
Part E Getting Started - ER450 User Interfaces Ports A & B RS232 Connector Pin outs (DCE) Port A and B, Female DB9 Typical pins used: Activating the Transmitter Caution...
Page 27
Part E Getting Started- ER450 Power Supply Requirements TVIEW+ Management Suite Radio Configuration Caution MUST re-check...
Optimising the Antenna for best RX LED Indicators & Test Outputs signal LED Legend Radio is Powered PWR Radio Errors Analog RSSI Output Characteristics - E Series Data Radio Port A Port B Synch/ Pwr/TX Error Diagnosis RXSig External Supply Voltage out of spec.
Page 29
Part E Getting Started- ER450 Received Signal Indicator Verifying Operational Health LED Legend RX/SYNC Note: Port A and Port Bs RxD and TxD will be Active on Data Flow Full Duplex PTP Master or Slave Note: This might only be apparent on a PTMP slave when only receiving.
Part E Getting Started - EB450 EB450 Quick Start Guide Introduction Quick Start Guide for the EB450 Base / Repeater Data Radio Mounting and Environmental External Duplexer Considerations Considerations Connecting Antennas and RF Feeders See ER450 Quick Start Guide Communications Ports See ER450 Quick Start Guide Section Power Supply and Protection...
Need help?
Do you have a question about the E Series and is the answer not in the manual?
Questions and answers