Summary of Contents for Trio Datacom E Series

  • Page 1 User Manual E Series Data Radio ER450 Remote Data Radio EB450 Base Station EH450 Hot Standby Base Station www.trio.com.au Issue 5: February 2004...
  • Page 2: Table Of Contents

    Related Products Remote Diagnostics & Other Related Documentation and Products Network Controller Revision History Introduction Part B – E Series Overview System Description Definition of E Series Data Radio Operating Instructions E Series Product Range Interpreting Poll Results E Series – Features and Benefits...
  • Page 3 SECTION 1 Part A - Preface Part B - E Series Overview Part C - Applications Part D - System Planning and Design Part E - Getting Started Part F - Operational Features Part G - Commissioning Part H - Maintenance...
  • Page 4: Part A – Preface

    Part A - Preface Part A – Preface Warranty Warning - RF Exposure Compliance Information FCC Notice (Hot Standby Controller Only) Important Notice © Copyright 2002 Trio DataCom Pty Ltd All Rights Reserved IC Notice (Hot Standby Controller Only) R&TTE Notice (Europe)
  • Page 5: Related Products

    Part A - Preface Related Products Other Related Documentation and Products Revision History...
  • Page 6: Part B – E Series Overview

    Part B – E Series Overview Part B – E Series Overview Definition of E Series Data Radio E Series – Features and Benefits Common Features and Benefits of the E Series Data Radio E Series Product Range half duplex...
  • Page 7 Part B – E Series Overview Features and Benefits of EH450 Hot Standby Base / Repeater Station Features and Benefits of ER450 Remote Data Radio Features and Benefits of EB450 Standard Base / Repeater Station...
  • Page 8: Model Number Codes

    0 - 5 2 - D The above example specifies: E Series, Remote Radio, generic 450MHz band, with a specific frequency of 450MHz to 465MHz, a 96/19.2kbps modem, with a bandwidth of 25kHz, diagnostics and standard N type connector. Version: 3/03...
  • Page 9: Standard Accessories

    Part B – E Series Overview Standard Accessories Part Number Description Part Number Description Duplexers RF Cables and Accessories DUPLX450BR NM/NM/TL NM/NM/TLL DUPLX450BR/5 RFCAB5M RFCAB5M2 DUPLX450BP RFCAB10M RFCAB20M Notes: Frequencies must be specified at time of order. RFCAB20M4 Interconnecting (Feeder Tail) cables must be ordered separately for Externally fitted Duplexers.
  • Page 10: Part C – Applications

    Part C – Applications Part C – Applications Application Detail Generic Connectivity SCADA Systems Telemetry Systems Industries and Applications Information Systems...
  • Page 11: Systems Architecture

    Part C – Applications Systems Architecture Point-to-Point Point-to-Multipoint Systems...
  • Page 12 Part C – Applications Digipeater Systems Backbone Store and Forward Systems Digipeater System Backbone Store and Forward System...
  • Page 13: Part D – System Planning And Design

    Part D – System Planning and Design Part D – System Planning and Design Understanding RF Path Requirements...
  • Page 14: Examples Of Predictive Path Modelling

    Part D – System Planning and Design Examples of Predictive Path goodpath.pl3 Major Repeater Site Field Site Modelling 756.69 309.67 Elevation (m) Latitude 031 04 37.49 S 030 56 24.00 S Clear line of site Longitude 150 57 26.34 E 150 38 48.00 E Azimuth 297.05...
  • Page 15 Part D – System Planning and Design Effect of Earth Curvature on Long Paths longpath.pl3 Repeater Site Far Field Site Elevation (m) 221.26 75.58 Latitude 032 01 21.63 S 032 33 00.00 S Longitude 142 15 19.26 E 141 47 00.00 E 217.12 37.37 Azimuth...
  • Page 16: Selecting Antennas

    Part D – System Planning and Design Selecting Antennas Tuning the Antenna Antenna Placement Antenna Gain Alignment of Directional Antennas...
  • Page 17: Data Connectivity

    Part D – System Planning and Design RF Feeders and Protection Data Connectivity The V24 Standard data terminal equipment data communication equipment Note: All ETSI installations require the use of a lightning surge arrestor in order to meet EN6095. See Part A - Preface for lightning arrestor specifications.
  • Page 18 Part D – System Planning and Design Cable Wiring Diagrams...
  • Page 19 Part D – System Planning and Design Cable Wiring Diagrams RS232 Connector Pin outs (DCE) Port A and B, Female DB9...
  • Page 20: Power Supply And Environmental Considerations

    Part D – System Planning and Design Power Supply and Environmental Considerations General Note: Operation below the minimum specified supply voltages could result in poor radio performance. If the supply voltage falls below 7.2Vdc the radio will shut down. Normal radio startup will not occur until 10Vdc is supplied.
  • Page 21: Physical Dimensions - Remote Data Radio - Er450

    Part D – System Planning and Design Physical Dimensions - Remote Data Radio - ER450...
  • Page 22: Physical Dimensions - Base Station - Eb450

    Part D – System Planning and Design Physical Dimensions - Base Station - EB450...
  • Page 23: Physical Dimensions - Hot Standby Base Station - Eh450

    Part D – System Planning and Design Physical Dimensions - Hot Standby Base Station - EH450...
  • Page 24: Part E – Getting Started

    Part E – Getting Started - ER450 Part E – Getting Started ER450 Quick Start Guide Mounting and Environmental Considerations Introduction ER450 Quick Start Guide Note: In high power or high temperature applications, it is desirable to mount the radio with the heatsink uppermost to allow ventilation for the heatsink.
  • Page 25 Part E – Getting Started - ER450 ER450 Connections Layout System Port Description DB9 Female Pin 1 System port data out (RS232) Pin 2 Pin 2 System port data in (RS232) Pin 3 Pin 3 Factory Use Only - Do not connect No Connection Pin 4 Shutdown No Connection...
  • Page 26 Part E – Getting Started - ER450 User Interfaces – Ports A & B RS232 Connector Pin outs (DCE) Port A and B, Female DB9 Typical pins used: Activating the Transmitter Caution...
  • Page 27 Part E – Getting Started- ER450 Power Supply Requirements TVIEW+ Management Suite Radio Configuration Caution MUST re-check...
  • Page 28: Led Indicators

    Optimising the Antenna for best RX LED Indicators & Test Outputs signal LED Legend Radio is Powered “PWR” Radio Errors Analog RSSI Output Characteristics - E Series Data Radio Port A Port B Synch/ Pwr/TX Error Diagnosis RXSig External Supply Voltage out of spec.
  • Page 29 Part E – Getting Started- ER450 Received Signal Indicator Verifying Operational Health LED Legend “RX/SYNC” Note: Port A and Port B’s RxD and TxD will be Active on Data Flow Full Duplex – PTP Master or Slave Note: This might only be apparent on a PTMP slave when only receiving.
  • Page 30: Eb450 Quick Start Guide

    Part E – Getting Started - EB450 EB450 Quick Start Guide Introduction Quick Start Guide for the EB450 Base / Repeater Data Radio Mounting and Environmental External Duplexer Considerations Considerations Connecting Antennas and RF Feeders See ER450 Quick Start Guide Communications Ports See ER450 Quick Start Guide Section Power Supply and Protection...