Speck pumps Badu Stream II Installation Manual

Counter swimming unit

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Speck pumps Badu Stream II

  • Page 2 Website: www.usa.speck-pumps.com Email: technical.usa@speck-pumps.com Date of Installation: Installed by: Serial Number: For Service Call: Manufactured by Speck Pumps, Jacksonville Florida USA, ©2021 All Rights Reserved. This document is subject to change without notice. 2999999189 - Rev. 0920 - SW FA.300.JP...
  • Page 4: Important Safety Instructions

    AND DROWNING. Install this equipment in accordance with the instructions provided. As the manufacturer, Speck Pumps-Pool Products, Inc., hereby certifies that their Swim Jet Combination Fitting meets or exceeds the requirements of the Virginia Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/ APSP 16-2011 standards and safety regulations as set forth by the Consumer Products Safety Commission.
  • Page 7: General Description

    Stream II ® The Badu SwimJet Systems from Speck Pumps are designed to be installed during the construction of your pool to create a water treadmill for anyone wanting a therapeutic and effective exercise. The Badu SwimJet Systems can be installed in any type of pool, large or small, from gunite to vinyl liner. It has no protruding parts ensuring pool user’s safety, is very compact and installs at minimal cost.
  • Page 8: Plumbing Installation

    Plumbing Installation CAUTION: The discharge connection is at the center of the back of the jet housing. The suction connection is at the bottom of the jet housing. CAUTION: The suction line should remain below water level from the suction connection at the jet housing to a point directly beneath the pump.
  • Page 9 Plumbing Installation - continued 10” - 12” from center to center Figure 1 Two Jet (10” - 12” from center to center) 10” - 12” from center to center 10” - 12” from center to center Figure 1A Three Jet (10” - 12” from center to center) NOTE: Suction lines which are too long have significant disadvantages: Higher resistance which results in less efficient priming and a higher risk of cavitation.
  • Page 10 Plumbing Installation - continued NOTE: The BaduSteam assembly package contains all necessary parts for the installation of the unit into concrete, gunite, liner or fiberglass pools. CAUTION: All necessary screws and bolts included with the BaduStream are stainless steel. ALL screw threads and threaded inserts are METRIC! ONLY METRIC bolts and nuts may be used! The two exceptions are the suction and discharge connections on the BaduStream and pump housing (4”...
  • Page 13 Concrete or Gunite Installation NOTE: The following parts ARE NOT USED IN A GUNITE or CONCRETE INSTALLATION: Clamping Ring Gasket (Part #12) 1/4-20 x 1-1/2” Bolt (Part #18) 1/4-20 Nut (Part # 19) 1/4” Washer (Part #20) Air Regulator Gasket 60 x 11 x 2 mm (Part #21) #14 x 1”...
  • Page 14 Concrete or Gunite Installation - continued The air regulator can be located in the tile above the water level or in the deck. When tiling the pool, adjust the air regulator location so it is 3”-4” ABOVE the water level. Place and set with hydraulic cement. The air regulator holder (part #17) should finish flush with the inner pool wall.
  • Page 15: Liner And/Or Fiberglass Pool Installation

    Liner and/or Fiberglass Pool Installation 1. Using the clamping ring (part #3) as a template, drill holes in the pool wall for installation. The center line of the clamping 0.25” ring should be 12” BELOW the water level (See Figures 15 & 16).
  • Page 16 Removal of Liner When replacing liner or removing liner for repairs; remove the four (4) screws (part #9/1) which hold the square cover (part #8) to the jet housing. Remove all screws (part #9/2, 9/3 & 9/4) except the top two, which hold the clamping ring (part #3) and gasket (part #12) to the jet housing.
  • Page 17 Electrical - SPECK Controller Installation - Continued Figure 17 Control Box Wiring Power from main panel (230 VAC): Power to pump motor (230 VAC): Connection for remote relay Neutral, Line 1, Line 2 Load 1, Load 2 (Remove Jumper) BLK-2 RED-2 RED-4 BLK-4...
  • Page 18 Electrical - SPECK Controller Installation - Continued Figure 17A Control Box Wiring Power from main panel (230 VAC): Power to pump motor 1 Power to pump motor 2 Connection to remote relay Neutral, Line 1, Line 2 (230 VAC): Load 1, Load 2 (230 VAC): Load 1, Load 2 (120 VAC) BLK-2...
  • Page 19 Electrical - SPECK Controller Installation - Continued Table 1 LED Touch Button Color Codes COLOR MEANING Solid BLUE SwimJet System is OFF Flashing GREEN every 1 second SwimJet System is ON with 2 hour timer Flashing GREEN every 1/2 second This is a 2 minute warning on the 2 hour timer.
  • Page 20: Nozzle Adjustment

    Service and Maintenance Nozzle Adjustment The BaduStream System is provided with a set of nozzle adjustment tools. These tools will allow the user to set the jet nozzles into position for optimum performance. When setting the nozzles for basic swimming, it is recommended that you set the nozzles in such a way that each nozzle intersects 4 feet away while breaking the surface at the same time.
  • Page 21: Frequently Asked Questions

    Frequently Asked Questions How is the current generated? The pump generates up to 400 GPM coming out of two (2) jet nozzles at 27 ft. per second and 36 ft. per second thru one (1) nozzle creating a swim current in excess of 5700 GPM, measured 6 ft. from the jet. What size pool do I need? The BaduStream can be installed in any size pool.
  • Page 22: Troubleshooting

    Trouble Shooting PROBLEM POSSIBLE CAUSES SOLUTION 1. Pump will not prime. a. Suction air leak. Make sure the red filler plug and o-ring are clean and properly positioned. Tighten red filler plug. Tighten all pipes and fittings on suction side of the pump. Be sure water in the pool is high enough to flow through the jet housing.
  • Page 23 Trouble Shooting - continued PROBLEM POSSIBLE CAUSES SOLUTION 7. Motor overload a. Motor is not connected properly. Check wiring diagram on motor. protection “kicks out”. b. Low voltage due to under size Check with volt meter. Increase size of supply wire. wire or low incoming voltage.
  • Page 24: Product Specification

    Product Specification 11/2 11/1 10 4 Nozzle Adjustment Tool...
  • Page 25: Replacement Parts

    Replacement Parts Drawing Order # Number Required Description 2306002009 FACE RING - NOZZLE 5879006021 THREAD CUTTING SCREW - FACE RING K60 x 20 A2 2308762004 RING - CLAMPING 2302002857 NOZZLE - ADJUSTABLE FLOW 40mm 2308761001A 5 & 7 HOUSING WITH BUSHING REDUCER 16 x 1/4” 2308750003 COVER - SQUARE WHITE 5879650625...
  • Page 26: Limited Warranty

    BADU SwimJet System(s). 2. To the fullest extent permitted by law, the Limited Warranty will be void and of no force or effect and Speck Pumps-Pool Products, Inc. will have no liability, responsibilities or obligations to Buyer or with respect to the BADU SwimJet System(s) in the event of the occurrence...
  • Page 27 Buyer’s protection to the manufacturer at 8125 Bayberry Road, Jacksonville, Florida 32256 USA. Under no condition will products be accepted after the expiration of the Limited Warranty Period. Speck Pumps-Pool Products, Inc. shall not bear any costs or risks incurred by Buyer in shipping a defective BADU SwimJet System(s) to Speck Pumps-Pool Products, Inc.

Table of Contents