Operating Liquid; Medium To Be Pumped; Operating Connections; Mechanical Seal - Ohio Medical Corporation SM30B Operating Instructions Manual

Motor mounted liquid ring vacuum pump
Table of Contents

Advertisement

9.2.4 Operating liquid

9.2.4.1 Water
C AU T I O N
Risk of material damage caused by corrosion and
deposits in the pump due to poor water quality!
▶ If possible, use operating water featuring the following
quality.
 Th e following recommendations apply to operating
water temperatures < 122 °F.
Hydrological data
pH value
Conductivity
Total hardness
Carbonate hardness
Carbonate hardness with
hardness stabilisation
Chloride Cl
Sulphate SO4
Ammonium NH4
Iron Fe
Manganese Mn/copper
Cu
Free of solids / rust
Tab. 20 Hydrological data for operating water
▶ For higher temperatures, the hardness, conductivity and
chloride values must be reduced.
C AU T I O N
Risk of material damage caused by deposits from the
overall cycle, which may enter the pump!
▶ Use non-corrosive materials in the overall cycle.
▶ Ensure that deposits from the overall cycle cannot
enter the pump.
Th e manufacturer does not accept liability for
corrosion damage to pump parts.
Th e manufacturer recommends seeking the advice of
a company specialised in water treatment and water
maintenance (e.g. www.schweitzer-chemie.de ) to
provide adequate corrosion protection.
9.2.4.2 Other operating liquids
When using operating liquids other than water, please
contact the manufacturer.
Max.
Unit of Measure
7.0 – 9.0
-
10...150
mS/m (t = 25 °C)
< 15
°dH
< 4
°dH
< 15
°dH
< 100
mg/l
< 150
mg/l
< 1
mg/l
< 0.2
mg/l
< 0.1
mg/l
< 0.1
mg/l
29
9.2.4.3 Flow rate, delivery of liquids, fi lling volume
Type
Flow rate
[GPM]
80 mbar/59
SM30B
SM55B
SM75B
SM100B
SM200B
SM250B
Tab. 21 Flow rate, delivery of liquids, fi lling volumes

9.2.5 Medium to be pumped

Gases and vapours
dry or wet, not explosive, infl ammable, aggressive
or toxic
air or air-steam mixtures
− which are free of solids
− which contain small amounts of light particulate
matters
For explosive, infl ammable, aggressive or toxic gases
and vapours, please consult the manufacturer.

9.2.6 Operating connections

Type
Process water
connection
Size
SM30B
1/4"
SM55B
1/2"
SM75B
1/2"
SM100B
1/2"
SM200B
1"
SM250B
1"
Shape: T = Th read, F = Flange
Tab. 22 Operating connections

9.2.7 Mechanical seal

All aggregates are fi tted with mechanical seals.
Typical features are
− single seal
− not pressure-relieved
− conical spring
− dependent on the direction of rotation
255548 Rev.1
Max.
liquid
o
F
delivery
[m
3
/h]
4.8
0.6
4.0
1.8
4.0
1.8
4.4
2
6.0
2.8
7.1
3.2
Suction
connection
Shape
Size
Shape
T
1"
T
T
1 1/2"
T
T
1 1/2"
T
T
2"
T
F
2 1/2"
T
F
3"
T
Filling
volume up
to middle
of the shaft
[QT]
0.4
3.0
3.4
4.2
4.5
5.0
Pressure
connection
Size
Shape
1"
T
1 1/2"
T
1 1/2"
T
2"
T
2 1/2"
F
2 1/2"
T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm55bSm75bSm100bSm200bSm250b

Table of Contents