iGen SAR-100 Installation Instruction

Smart anti-rejectionbox

Advertisement

Quick Links

User Manual
Installation Instruction for Smart Anti-rejection Box
Model: SAR-100
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAR-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for iGen SAR-100

  • Page 1 User Manual Installation Instruction for Smart Anti-rejection Box Model: SAR-100...
  • Page 2: Table Of Contents

    User Manual Contents Ⅰ Introduction ......................... 3 Ⅱ Parameters ...........................3 Ⅲ Product Installation ......................4 3.1 Tool ..........................4 3.2 Location ........................4 3.3 Notice ..........................4 ⅣAnti-rejection System Diagram ................... 5 ⅤDevice Installation ........................ 6 5.1 Installation ........................6 5.2 Device wiring ........................6 Ⅵ...
  • Page 3: Ⅰ Introduction

    CT, which meets the requirement of real-time adjusting inverter output power at power consumption scenario. It can connect to many inverters and support data transmission via WiFi&Ethernet. Ⅱ Parameters Parameter Product Model SAR-100 Remote Communication 2.4G WiFi+Ethernet Local Communication RS 485 No.
  • Page 4: Ⅲ Product Installation

    User Manual Ⅲ Product Installation 3.1 Tool Table 3.1 Preparation Tool Tool Name Picture Usage Note Wire stripper Strip cable insulation Cross screwdriver Use to connect Cable Connect logger with router Shielded twisted pair Use to install anti-rejection Expansion Screw Specification: M6*60 Adjustable Wrench Use to fix expansion screws...
  • Page 5: Ⅳanti-Rejection System Diagram

    User Manual ⅣAnti-rejection System Diagram If 485 link communication is not successful for some inverters, please connect a 120Ωresistance with repeater and A&B point of the last inverter.
  • Page 6: Ⅴdevice Installation

    User Manual ⅤDevice Installation 5.1 Installation 1.Select a right (firm&flat) place to install the device 2. Determine the drilling hole positions according to hangers (Refer to Fig. 5.1) 3. Fix the device using expansion screws Fig. 5.1 Installation Diagram (Unit: mm) 5.2 Device wiring...
  • Page 7 User Manual Notice 1. Connect inverter output to the grid. Connect to phase line R ,S, T, N accordingly. 2. Connect voltage-sampling signal line, communication distance should be less than 100m. Connect to phase line R ,S, T, N accordingly. 3.
  • Page 8: Ⅵ Networking Configuration

    User Manual Ⅵ Networking Configuration Notice: 1. DIN-Rail logger supports WiFi&Ethernet access. Please select one method to access according to actual situation. 6.1 WiFi Access Go to DIN-Rail logger configuration page Step 1 Prepare a computer/smart phone that can connect to wireless network Step 2 Connect to logger AP (Please do Not connect the cable when configuring the logger) Select and connect AP XXXXXXXXX in the network list (XXXXXXXXX means logger SN) Step 3 Log in to logger WEB page...
  • Page 9 User Manual Step 4 During the first login, the browser will remind you whether to save the password. You can decide according to your usage habit. Step 5 During the first login, the system will prompt that the AP is not encrypted. Click OK to encrypt it, click Cancel if not. Step 6 If you choose to encrypt AP, you will go to “AP Encryption Modification”, enter your password and click Save.
  • Page 10 User Manual Step 7 Click Reboot after saving. After AP encryption has been set, you will be reminded again during network settings. If the following prompt shows, you can select "AP encryption modification" accordingly. Step 8 Refresh the WEB page and log in again. Username: admin Password: admin...
  • Page 11 User Manual Notice 1. Step 6-8 are for AP encryption. If you will not select AP encryption, skip step 6-8, click cancel in step 5 and go to step 9 directly. Step 9 Go to setup guide page. Click Start Step 10 Select Wireless connection and click Next...
  • Page 12 User Manual Step 11 Select router name and click Next, refresh the page if no target router listed Notice 1. Router name and password do not support 、;, = ' ” characters. 2. 5G WiFi is not supported. 3. Router DHCP function: ON. 4.
  • Page 13 User Manual Step 12 Set router password and click Next Step 13 If allocating fixed IP address is not required, select Obtain an IP address automatically: Enable (Recommended) and click Next Step 14 If allocating fixed IP address is required, select Disable Enter the target IP address and click Next...
  • Page 14 User Manual Step 15.1 If you wish to enhance safety, you can choose “ Hide AP ” or “ AP Encryption Modification ” . “ AP Encryption Modification ” is recommended. If you already set AP encryption, please refer to previous steps. Notice 1 If you select “Hide AP”, AP will be hided automatically.
  • Page 15 User Manual Step 16 Click OK to complete WiFi configuration Step 17 Connect AP again according to the notification around 40s. Log in to WEB page and check if the network is successful.
  • Page 16: Ethernet Access

    User Manual 6.2 Ethernet Access Use cable to connect DIN-Rail logger and router Notice 1. Ethernet port of DIN-Rail logger has no lighting function 2. Router DHCP function: ON Step 1 Select “ Cable connection ” , and set Wireless function: Enable. Click Next. (Otherwise, you can't connect to AP through mobile phone or computer for web page setting) Step 2 If allocating fixed IP address is not required, select Obtain an IP address automatically: Enable (Recommended) and click Next...
  • Page 17 User Manual Step 3 If allocating fixed IP address is required, select Disable Enter the target IP address and click Next Step 4 If you wish to enhance safety, you can choose “ Hide AP ” or “ AP Encryption Modification ” . “...
  • Page 18 User Manual Step 5 If enhancing safety is not required, click Next. System will remind you to encrypt AP, click Cancel. Step 6 Click OK to complete Ethernet configuration.
  • Page 19 User Manual Step 7 Connect AP again according to the notification. Log in to WEB page and check if the network is successful. If you need to enter the web page through IP address via LAN, please remember the actual IP address in "Wireless Mode". After the network setting is completed, you can enter the web page through two methods to set up anti-rejection.
  • Page 20: Anti-Rejection Setup

    User Manual Ⅶ Anti-rejection Settings 7.1 Anti-rejection setup Step 1 Click Advanced Setup- Anti-rejection setup Notice Default: Anti-rejection Function: ON Step 2 If anti-rejection function is required, select“Enable”, set inverter number, CT ratio and power. Inverter Number Instruction Inverter number: 10, and click save. (Set according to actual situation on site.) CT Ratio Setup Instruction If CT is 200/5A, please enter 40 and save.
  • Page 21 User Manual when the inverter power is set to 0.) If you set -100W, which means inverter production is used for load and there is still 100W for grid-tie. Please Note: If the inverter load power is less than min. production power, the surplus power will go on grid. Step 2.1 If anti-rejection function is not required, select“Disable”...
  • Page 22 User Manual Step 3 Click Restart Step 4 If the successful page is displayed, it means the anti-rejection setting is successful.
  • Page 23: Ⅷ Instruction For Indicator Light, Dial Switch And Reset Button

    User Manual Ⅷ Instruction for Indicator Light, Dial Switch and Reset Button 8.1 Indicator Light After DIN-Rail logger (WiFi/ETH) connected to the device and networking is normal, check the status of STATUS light, LINK light, 485/422 light. (There is only one light for each STATUS light, LINK light, 485/422 light.) Logger light Light Implication...
  • Page 24: Reset Button

    User Manual 8.3 Reset Button Light Implication Instruction Long press for 4s to reset the logger and Reset button restore factory settings. Ⅸ SOLARMAN Monitoring 9.1 Register and create a plant If you have a household PV plant, it is recommended to use SOLARMAN Smart. Scan the QR code below to download or go to Android/App Store searching for SOLARMAN Smart.
  • Page 25: Solarman Smart App

    User Manual 9.2 SOLARMAN Smart APP Step 1 Registration Go to SOLARMAN Smart APP and click“Register a new account”and select“E-mail”or“Phone Number”to register. Step 2 Create a plant Click“Add Now”. Choose“Yes”to select“Create Plant By Myself”. Choose“No”to select“Create Now”.
  • Page 26 User Manual Step 2.1 Users can select plant location automatically or enter plant location manually, then click“Next”. Users need to enter plant information here, click“Done”to complete. Step 3 Add a logger Click“Go to Add”, enter SN manually or scan bar code, then click“Add”. Step 3.1 Click“Skip”to return homepage and click plant name to visit a plant.
  • Page 27 User Manual Step 4 Select associated device After the logger is added, system will go to“Select associated device”, if you will not change associated method, click “Done”. If you are going to change associated method, click“Manual selection”. (Network configuration has been done at step 6) Click“Later”to return to homepage.
  • Page 28 User Manual Step 5 Meter configuration Click plant name to visit a plant. (If you are in plant details page, you can click “ Device ” directly) Click “ Device”- “ Meter ” - “ Meter configuration”, go to select “ Three-phase System ” - “ Grid ” , click a blue arrow in CT direction and change to “...
  • Page 29: Solarman Business App

    User Manual 9.3 SOLARMAN Business APP Step 1 Registration Go to SOLARMAN Business APP and click“Register”-“Switch to E-mail registration”. Tick“T&Cs”and click“Next”. Select“Business Type”, enter“Business Name”, select“Business Area”, select“Type” and click“Next”. If you already have an account, click“Click here”to return to login page. The following page will display and click“Finished and Log In”to return to login page.
  • Page 30 User Manual Step 2 Create a plant Click“+”in the upper right corner, select“Create a Plant”and enter plant information, then click“Save”. Step 3 Add a logger Click“Add Data logger”, enter SN manually or scan bar code, then click“Done”. Step 3.1 If not, click“Done”to return to“Dashboard”. Click “...”...
  • Page 31 User Manual Notice Logger SN will be displayed in the device list after 10 mins. Step 4 Meter configuration Click “ Devices”, choose target meter and click “ Meter configuration”, go to select “ Grid ” , click a blue arrow in CT direction and change to “...
  • Page 32: Ⅹ Contact

    User Manual Ⅹ Contact IGEN Tech Co., Ltd. Add: Block F4, China IoT International Innovation Park, No. 200, Linghu Avenue, Wuxi, Jiangsu, P. R. China Tel: +86-400-181-0512 Email: info@solarmanpv.com Website: www.solarman.cn...

Table of Contents