Scope Of Delivery; Intended Purpose And Disclaimer; Connectors And Cables; 1000Base-T1 / 100Base-T1 Connector - I-novative Auto-Link-SPE-G User Manual

Table of Contents

Advertisement

3

Scope of Delivery

Auto-Link-SPE-G (1000Base-T1 Media Converter)
T1 Network Connector Receptacle (Molex Mini50 4Pos)
Power Connector Receptacle (Molex Mini50 2Pos)
Terminals for the Mini50 Receptacles (4x AWG22 + 4x AWG24 + 4x AWG26-30)
4

Intended Purpose and Disclaimer

The Auto-Link-SPE-G is intended to be used for development and testing purposes in automotive or
industrial areas.
It is not allowed to use the Auto-Link-SPE-G in series products.
Warranty Exclusion: i-novative
the use of the Auto-Link-SPE-G.
5

Connectors and Cables

5.1

1000BASE-T1 / 100BASE-T1 Connector

5.1.1 Receptacle Specification

MINI50 4Pos Receptacle Opt A
Connector
MINI50 4Pos Receptacle Opt A
CTX50 Terminal L-Grip 22 AWG
Terminals
CTX50 Terminal M-Grip 24 AWG
CTX50 Terminal S-Grip 26-30 AWG

5.1.2 Pin Assignment

5.1.3 T1 Cable Recommendation

For proper operation of the link, the used network cables and connectors for the T1 link must
comply to the specifications of the respective standards. Please refer to:
100BASE-T1: "IEEE 802.3bw Clause 96.7"
1000BASE-T1: "IEEE 802.3bp Clause 97.6"
Auto-Link-SPE-G User Manual
Rev. 1.6
2020-07-05
®
GmbH does not take over any liability for damages resulting from
Description
Vendor
Part Number Distributor Distributor Number
Molex
347910040
Molex
347910140
Molex
5600230448
Molex
5600230421
Molex
5600230444
Pin
Signal
1
Shield
2
Data P
3
Data N
4
Shield
Digi-Key
WM9381-ND
Digi-Key
WM19983-ND
Digi-Key
WM16315CT-ND
Digi-Key
WM8745CT-ND
Digi-Key
WM25289CT-ND
Remark
4 / 10