Symptom
Image is
blurred;
background
is lightly
stained;
there is
insufficient
gloss of the
printed
image.
The print or
color density
is uneven.
Irregular
print or mot-
tled image
appears.
86
Cause
One or more of the
toner cartridges are
defective.
The drum cartridge is
defective.
One or more of the
toner cartridges are
defective or low.
The drum cartridge is
defective.
The printer is not
level.
The media is moist
from humidity.
Unsupported media
(wrong size, thick-
ness, type, etc.) is
being used.
One or more of the
toner cartridges are
defective.
The drum cartridge is
defective.
The fuser separator
levers are adjusted
for envelope printing.
Solving Problems with Printing Quality
Solution
Remove the toner cartridge and check
for damage. If it is damaged, replace it.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Install new toner cartridges.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Put the printer on a flat, hard, level sur-
face not to exceed ±1° slant in any
direction.
Adjust the humidity in the media stor-
age area.
Remove the moist media and replace it
with new, dry media.
Use KONICA MINOLTA-approved
media. See "Media Specifications" on
page 24 for supported sizes.
Remove the toner cartridge and check
for damage. If it is damaged, replace it.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Return the fuser separator levers to
the plain paper setting.