Indoor/Outdoor Unit Installation Drawings
The models adopt HFC free refrigerant R32.
For installation of the indoor units, refer to the installation manual which was provided with the units.(The
diagram shows a wall-mounted indoor unit.)
more than 20cm
more than 10cm
Arrangement of piping
directions.
Rear left
Lef t
Rear right
Below
The marks from
to
A
in the figure are the
parts numbers.
The indoor unit should
be installed at the
recommended height
(1.8m).
more than 60cm
1.When installing the unit to wall, roof or rooftop, fix a supporter surely with nails or wires in
preparation of earthquake and strong wind.
2.Air conditioner mounted not above and one meter away from electric equipment such as
television.
Please be subjected to the actual product purchased.
13
Right
more than 60cm
more than 10cm
F
Compressor(Inside of Unit)
Attention must be paid to
the rising up of drain hose.
more than 10cm
A
more than 10cm
more than 30cm
AIR OUTLET
AIR INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
B
Optional parts for piping
A
Non-adhesive tape
Piping hole cover
B
F
Saddle (L.S) with screws
C
Connecting electric cable for
D
indoor and outdoor
Drain hose
E
C
Heating insulating material
F
Fixing of outdoor unit
Fix the unit to concrete or
block with bolts(10mm)and nuts
firmly and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
D
a supporter surely with nails or
wires in consideration of
E
earthquake and strong wind.
If vibration may affect the house,
fix the unit by attaching a
vibration-proof mat.