Technical data
Description
Actual capacity of the water tank at 20°C
Outer diameter of the tank
Height of the appliance
Gross weight of the appliance
Net weight of appliance once filled with sanitary water
Material of element
Thermal insulation material
Thermal insulation of the tank, average thickness
IP classification
Standby heat losses / 24 hour
Standby heat losses
V40 Hotwater volume
Primary flowrate for Reheat time & Primary heating power
Heating coil HEX surface
Heating up time heating coil
Primary Heating power heating coil
Primary Heating coil pressure drop
Heat up time immersion heater
ErP class
Pressure information
Design pressure of cylinder (rated pressure)
Design pressure of heating coil
Operating pressure of cylinder
Operating pressure of heating coil
Max. operating temperature of cylinder
Max. operating temperature of heating coil
Hydraulic connections
Secondary return
Primary Heating coil Flow
Primary Heating coil Return
Cold water
Hot water
Immersion heater
T&P valve (factory fitted)
Temperature sensor sleeve diameter
Electrical characteristics
Supply voltage and frequency
Power of the electrical resistance
Electrical installation
Thermostat type - immersion/cylinder
Immersian Heater - Phase
Immersion thermostat - temp range
Immersion thermostat - set temp
Safety
Safety valve opening pressure +/- 5%
T&P valve opening pressure/Temp.
Safety thermostat cutout - immersion
Safety thermostat cutout - cylinder
These products are manufactured by OSO Hotwater AS, Industriveien 1, 3300 Hokksund, Norway.
Technical Data Sheet - Indirect storage tank - ErP data
Directive: 2010/30/EU
Water heater Efficiency according to standard: prEN50440 : 2015
M.T. ITEM No.
80341850
PAW-TD 20 C1E5-UK - 1,5kW / 1x230V
80341950
PAW-TD 30 C1E5-UK - 1,5kW / 1x230V
80341951
PAW-TD 30 C1E5HI-UK - 1,5kW / 1x230V
Regulation: EU 812/2013
MODEL/IDENTIFIER
PAW-
Unit
TD20C1E5-UK
L.
192
mm
595
mm
1270
kg
50
kg
241
-
incoloy 825
-
PUR+VIP
mm
50
-
21
kWh/24h
1.03
Watts
43
L.
315
l/h
900
1.8
min
18.5
kW
35
mbar
120
min
255
-
A
MPa/Bar
1 / 10
MPa/Bar
1 / 10
MPa/Bar
0.3 / 3
MPa/Bar
0.25 / 2.5
°C
70
°C
99
Inch
3/4"
Inch
3/4"
Inch
3/4"
Inch
3/4"
Inch
3/4"
Inch
5/4"
Inch
1/2"
mm
8
WHz
220-240 VAC
kW
1.5kW@230V
-
IEEE regs
-
Probe/Probe
Phase
single
°C
8-70
°C
60
MPa/Bar
0.8 / 8
MPa(Bar) /°C
1/90 (10/90)
°C
87
°C
80
Directive: 2009/125/EU
Rating ErP
A
A
A
PAW-
PAW-
TD30C1E5-UK
TD30C1E5HI-UK
284
280
595
595
1750
1750
61
341
345
incoloy 825
incoloy 825
PUR+VIP
PUR+VIP
50
21
1.18
1.18
49
465
389
900
900
1.8
2.35
26.08
18.5
32
39.4
120
170
464
384
A
1 / 10
1 / 10
1 / 10
1 / 10
0.3 / 3
0.3 / 3
0.25 / 2.5
0.25 / 2.5
70
99
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
5/4"
5/4"
1/2"
1/2"
8
220-240 VAC
220-240 VAC
1.5kW@230V
1.5kW@230V
IEEE regs
IEEE regs
Probe/Probe
Probe/Probe
single
single
8-70
8-70
60
0.8 / 8
0.8 / 8
1/90 (10/90)
1/90 (10/90)
87
80
Regulation: EU 814/2013
Heat loss - W
Storage vol.
43
192
49
284
49
280
65
50
21
49
A
70
99
8
60
87
80
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Paw-td30c1e5-ukPaw-td30c1e5hi-uk

Table of Contents